Installation Instructions
Installer Setting - Dry Contact Mode Setting
Dry contact function is the function that is possible to use only when dry contact equipment is
separately purchased/setup.
•
Please refer to dry contact manual for more details.
20 New Wide Wired Remote Controller
1
Pressing and holding the
button
for 3 seconds enters the remote
controller setup mode. If it is not held
for 3 seconds, it enters the user setup
mode.
2
If pressing
button repeatedly, it moves to
remote controller dry contact mode setup
menu as pictured below.
Select Dry contact setting by pressing
3
button.
(00 : Manual, 01 : Automatic)
Function Code
Dry Contact
setting value
4
Press
button to save.
5
Pressing the
button will exit the settings
mode. If
is not pressed, the remote
controller will automatically exit setup mode
after 25 seconds with no input. If the set
button is not pressed, the changes will not
take effect.
Installer Setting - Zone State
It is the function to setup indoor unit's wind flow to variable or fixed.
- Variable : Comp ON, setup airflow. Comp OFF, weak wind
- Fixed : Comp ON, setup airflow. Comp OFF, setup airflow
Installation Instructions
1
Pressing and holding the
button
for 3 seconds enters the remote
controller setup mode. If it is not held
for 3 seconds, it enters the user
setup mode.
2
If moving to ceiling height selection menu by
pressing
button, it indicates as pictured
below.
3
Select Zone State rate fixing mode by
pressing
button.
(01: Variable, 02: Fixed)
Function Code
Zone State
fixing mode
4
Press
button to save.
5
Pressing the
button will exit the settings
mode. If
is not pressed, the remote
controller will automatically exit setup mode
after 25 seconds with no input. If the set
button is not pressed, the changes will not
take effect.
Owner's & Installation Manual 21