hit counter script
LG PQRCVSL0 Owners & Installation Manual

LG PQRCVSL0 Owners & Installation Manual

New wide wired remote controller for air conditioner
Hide thumbs Also See for PQRCVSL0:
Table of Contents

Advertisement

OWNER'S &
INSTALLATION MANUAL
AIR
CONDITIONER
Please read this owner's & installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
Please retain this owner's & installation manual for future reference after reading it thoroughly.
New Wide Wired Remote Controller
PQRCVSL0
PQRCVSL0QW
www.lg.com
P/No.: MFL62129202

Advertisement

Table of Contents
loading

Summary of Contents for LG PQRCVSL0

  • Page 1 Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this owner's & installation manual for future reference after reading it thoroughly. New Wide Wired Remote Controller PQRCVSL0 PQRCVSL0QW www.lg.com P/No.: MFL62129202...
  • Page 2: Table Of Contents

    New Wide Wired Remote Controller Owner’s & Installation Manual Safety Precaution TABLE OF CONTENTS Safety Precaution • The installation requires expert skills, and it should be installed by the service center or other shops specialized Safety Precaution ..............................3 in the installation and recognized by our company. Part Description................................4 •...
  • Page 3: Part Description

    Part Description Installation Instructions Installation Instructions Part Description Name and Function of Remote Controller 1. Please fix tightly using the provided screws after placing remote controller setup board on the place where you plan to place the remote controller. - Please set it up not to bend because poor setup could take place if setup board bends. OPERATION INDICATION Please set up remote controller board fit to the reclamation box if there is a reclamation box.
  • Page 4: Group Control

    Installation Instructions Installation Instructions 3. Place the top part of the remote controller into Group control Connecting order the setup board you have screwed into the wall, 1. When installing more than 2 as pictured to the right, and connect the pieces units of air conditioner to one by pressing the bottom into the board.
  • Page 5: Installer Setting - How To Enter Installer Setting Mode

    Installation Instructions Installation Instructions Installer Setting Code Table Installer Setting - How to enter installer setting mode 1) General air-conditioner product Function Code Value CAUTION Test Run 01:Set If the installation is not done correctly it can cause injury to the user or damage to your property. Address Setting 00~FF : Address Installation must be done by a certified HVAC technician, and any problems arising from improper...
  • Page 6: Installer Setting - Test Run Mode

    Installation Instructions Installation Instructions Installer Setting - Test Run Mode 2) General Ventilation product After installing the product, you must run a Test Run mode. Function Code Value For details related to this operation, refer to the product manual. Test Run 01 : Test Run Setup Address Setting 00~FF : Address of Central Control...
  • Page 7: Installer Setting - Setting Address Of Central Control

    Installation Instructions Installation Instructions Installer Setting - Setting Address of Central Control Installer Setting - E.S.P. It's the function to use for connecting central control. This function allows the wind strength for each fan speed level to be set manually. Please refer to central controller manual for the details •...
  • Page 8: Installer Setting - Thermistor

    Installation Instructions Installation Instructions Installer Setting - Thermistor Select ESP fan step again by using This is the function to select the temperature sensor to judge the room temperature. button and set up the ESP value, as No. 4 and 5, that corresponds to each wind Pressing and holding the button flow.
  • Page 9: Installer Setting - Ceiling Height Selection

    Installation Instructions Installation Instructions Installer Setting - Ceiling Height Selection Installer Setting - Static Pressure Setting This function is to adjust FAN Airflow rate according to ceiling height (for ceiling type product) This function is applied to only duct type indoor units. Setting this in other cases will cause malfunction. Pressing and holding the button Press and hold the...
  • Page 10: Installer Setting - Remote Controller Master/Slave Setup

    Installation Instructions Installation Instructions Installer Setting - Remote Controller Master/Slave Setup Installer Setting - Override Master/Slave Setting It is a function for settings in group control, or 2-remote controller control. Override master/slave selection function to prevent indoor units operate as cooling and heating mode at same time.
  • Page 11: Installer Setting - Dry Contact Mode Setting

    Installation Instructions Installation Instructions Installer Setting - Dry Contact Mode Setting Installer Setting - Zone State It is the function to setup indoor unit's wind flow to variable or fixed. Dry contact function is the function that is possible to use only when dry contact equipment is - Variable : Comp ON, setup airflow.
  • Page 12: Installer Setting - Celsius / Fahrenheit Switching

    Installation Instructions Installation Instructions Installer Setting - Celsius / Fahrenheit Switching Installer Setting - Zone Type Setting This function is used for switching the display between Celsius and Fahrenheit. This function is only available on some products. It is possible to set up a new zone or select an old one to install the damper controller. Pressing and holding the button for CAUTION...
  • Page 13: Installer Setting - Zone Number Setting

    Installation Instructions Installation Instructions Installer Setting - Zone Number Setting Installer Setting - Emergency Heater Setting This function is only available on some products. This function is only available on some products Zone Number is to set the number of installed zones. It is possible to control only in zone new type This function will set the Emergency Heater Setting.
  • Page 14: Installer Setting - Option Function Setting

    Installation Instructions Installation Instructions Installer Setting - Option Function Setting Move to Low Ambient Heating Operation setting by pressing button. Setting feature for indoor unit when Plasma purification / Electric heater / Humidifier / Elevation grill Ventilation kit / Auxiliary heater is newly installed, or installed unit is removed. Pressing and holding the button for 3 seconds enters the remote...
  • Page 15: Installer Setting - Static Pressure Step Setting

    Installation Instructions Owner's Instructions Installer Setting - Static Pressure Step Setting Owner's Instructions This function is applied to only duct type. Setting this in other cases will cause malfunction. Standard Operation - Standard Cooling This function is only available on some models. This is the function that static pressure of the product is divided in 11 steps for setting.
  • Page 16: Standard Operation - Power Cooling

    Owner's Instructions Owner's Instructions Standard Operation - Power Cooling Standard Operation - Dehumidification Mode It makes the room cool using pleasant and fresh air quickly It removes humidity while air-cooling slightly Press button to turn on the Press button to trun on the indoor unit.
  • Page 17: Standard Operation - Auto Operation Mode

    Owner's Instructions Owner's Instructions Standard Operation - Auto Operation Mode Standard Operation - Temperature Setting/Room Temperature Check Press button to turn on the Temperature Setting indoor unit. We can simply adjust the desired temperature. • Press the buttons to adjust the Press button to select desired temperature.
  • Page 18: Standard Operation - Airflow Setting

    Owner's Instructions Owner's Instructions Standard Operation - Airflow Setting Sub function - Direct Wind / Indirect Wind It is the function to directly or indirectly control wind direction by body perception sensor. Wind powerfulness : You can simply adjust desired wind powerfulness. The method to setup direct/indirect wind Please setup desired fan speed by Please press the...
  • Page 19: Sub Function - Plasma Purification

    Owner's Instructions Owner's Instructions Sub function - Plasma Purification Only products with humidifying function can use this. The method to cancel direct/indirect wind Please press the button. The method to setup cleaning air Press the button until the icons flashes. The icon of direct/indirect wind blinks on the display, and then, if pressing...
  • Page 20: Sub Function - Humidifier

    Owner's Instructions Owner's Instructions Sub function - Humidifier Sub function - Electric Heater It is a function to strengthen the heating ability by turning on the electric heater during the heating Only products with humidifying function can use this. operation. It can only be set during heating operation.
  • Page 21: Sub Function - Energy-Saving Cooling Operation

    Owner's Instructions Owner's Instructions Sub function - Energy-Saving Cooling Operation Sub function - Robot Cleaning Manual Setup Energy-Saving Cooling improves the user’s comfort by slowly changing the set temperature to an Robot cleaning function is the function for cleaner attached to the product to automatically clean the energy efficient setting .
  • Page 22: Function Setting - Child Lock

    Owner's Instructions Owner's Instructions Function setting - Child Lock Function setting - Robot Cleaning Automatic Setup Robot cleaning function is the function of cleaner attached to the product to automatically clean filter This feature locks the keypad to prevent any unwanted changes to the settings. when using air-conditioner for the specific period of time.
  • Page 23: Function Setting - Filter Sign Clear

    Owner's Instructions Owner's Instructions Function setting - Filter Sign Clear Function setting - Elevation Grill This function is to clear the indicator of indoor filter cleaning. This function is to move the indoor filter up/down for cleaning filter. Press button repeatedly Press the button until the until the...
  • Page 24: Function Setting - Vane Angle Control

    Owner's Instructions Owner's Instructions Function setting - Vane Angle Control Function Setting - Change Temp This function is to adjust angle at which airflow is blown out. Change temperature function can change a delta temperature of Auto change over function. The change temperature value consist certain gap between cooling and heating change over points.
  • Page 25: Function Setting - Zone Control

    Owner's Instructions Owner's Instructions Function setting - Zone Control Function setting - Changing Current Time This function turns any set zones on or off. Please press function setup button. If pressing function setup Press the button until the button repeatedly, it moves to icons flashes.
  • Page 26: Function Setting - Auto Cleaning

    Owner's Instructions Owner's Instructions Function setting - Auto Cleaning Press button to move to 'Minute' setting mode. (the 'Minute' segment will The method to setup Auto Cleaning flash) Please press button. Move to auto cleaning menu by pressing Setting Minute value by pressing button twice.
  • Page 27: Function Setting - Wlan(Wireless Lan) Module Access Point Mode

    Owner's Instructions Owner's Instructions Function Setting – WLAN(Wireless LAN) Module Access Point mode Programming - Simple Reservation It is the function to operate WLAN (Wireless LAN) module connected to the product in access point You can set the reservation conveniently in the units of 1 hour from 1 hour to 7 hours. mode.
  • Page 28: Programming - Sleep Reservation

    Owner's Instructions Owner's Instructions Programming - Sleep Reservation Programming - ON Reservation Automatically turned On at reserved time that you set. Sleep reservation is the function of air-conditioner to run and stop after a certain period of time at sleep mode before sleep. When connected to a ventilation product and set the sleep reservation, Press button.
  • Page 29: Programming - Off Reservation

    Owner's Instructions Owner's Instructions Programming - OFF Reservation Automatically turned Off at reserved time that you set. Pressing the button will exit the settings mode. If is not pressed, the Press button. remote controller will automatically exit setup mode after 25 seconds with no Ex) Setting OFF Reservation input.
  • Page 30: Programming - Weekly Reservation

    Owner's Instructions Owner's Instructions Programming - Weekly Reservation You can set the daily reservation in weekly unit. Weekly reservations operate until they are cancelled. Please move to reservation setup mode by pressing reservation button. Pressing the button will exit the ❈...
  • Page 31: Programming - Holiday Reservation

    Owner's Instructions Owner's Instructions Programming - Holiday Reservation Please move to 'AM/PM' setup part of turning off by using button. It automatically stops at reserved day that you set. - AM/PM setup is identical with turning on time setup. Please press button.
  • Page 32: Ventilation Product User Manual - Interlinked Air Conditioner And Ventilation

    Owner's Instructions Owner's Instructions Ventilation Product User Manual - Interlinked Air conditioner and Ventilation Ventilation Product User Manual - Interlinked operation with general ventilation It is used when air conditioner is interlinked with ventilation product. 1. Control using remote controller where air conditioner indoor unit and the It is a function that cools and refreshes indoor air using the ventilation product at the same time ventilation product is installed at the same time.
  • Page 33: Ventilation Product User Manual - Interlinked Operation With Direct Expansion Ventilation

    Owner's Instructions Owner's Instructions Manual Conversion - Pressing ‘Ventilation’ button in ventilation mode will manually convert Ventilation Product User Manual - Interlinked Operation with Direct Expansion Ventilation It is a function to cool and refresh the indoor air using general ventilation product.. It can only be used when the air conditioner is interlinked with direct expansion ventilation product.
  • Page 34: Ventilation Product User Manual - Single Operation With Direct Expansion Ventilation

    Owner's Instructions Owner's Instructions Ventilation Product User Manual - Single Operation with Direct Expansion Ventilation Ventilation Product Additional Operations - Fast / Power Saving Pressing It performs ventilation operation with cooling or heating at the same time using the heat It is a function to operate ventilation function more efficiently through the ventilation additional exchanger inside the direct expansion type ventilation product.
  • Page 35: Ventilation Product Function Settings

    Owner's Instructions Owner's Instructions Ventilation Product Function Settings Ventilation Product Reservations Settings Sleep Reservations : Sets to operate ventilation Delay Time : It operates after delay time in lightly during the sleep. ventilation operation. Press button to enter the Press Settings button.
  • Page 36: Ventilation Product Installer Setting Functions - Entering Method

    Owner's Instructions Owner's Instructions Ventilation Product Installer Setting Functions - Entering Method Different mode drive Different mode drive is a phenomenon taking place when indoor units' drive mode is different in the CAUTION case that a few indoor units are set up at one air handling unit. (Different mode drive does not show up at cooling exclusive model.) - Installer setting mode is a mode to set the detail functions of the remote controller.
  • Page 37: Self-Diagnosis For Trouble Mode

    Owner's Instructions Self-diagnosis for Trouble Mode Checkups before reporting breakdown Please first check the items below for product's defects before consulting to the service center. Symptoms Check-up Management • Is air-conditioner's power on? • Please check circuit breaker. • Please check wire remote controller's setup condition.

This manual is also suitable for:

Pqrcvsl0qw

Table of Contents

Uploaded: cache9/manual/1664047/Lg-Pqrcvsl0.html.gz