hit counter script

LG Therma V ZHBW056A0 Service Manual page 79

Air-to-water heat pump
Table of Contents

Advertisement

Code
Description
No.
15
Water pipe overheated
Start
NO
Leaving water
temperature is higher
than target water
YES
temperature
YES
NO
Thermostat is
installed
YES
NO
Leaving water
temperature is higher
than 57 °C
YES
Cause
• Abnormal operation of
electric heater
• Leaving water temperature
is above 57 °C
END
(it is normal
condition)
A
A
B
B
- 79 -
• Possible maximum leaving water
temperature is 57 °C.
• This is unexpected case.
• Turn off the system and call service center.
• If the system is not turned off before it yields
error code (CH15), very hot leaving water will
be generated and it is harmful to human.
• Room air is not fully heated by under floor
heating.
• Wait while room air is heated by target
temperature of thermostat.
Copyright © 2018 LG Electronics Inc. All rights reserved.
Only training and service purposes.
Normal Condition