Installation
• When extending the drain hose at the indoor unit,
install the drain pipe.
Drain pipe
Adhesive
6. Wrap the insulation material around the connect-
ing portion.
• Overlap the connection pipe insulation material
and the indoor unit pipe insulation material. Bind
them together with vinyl tape so that there is no
gap.
Plastic bands
• Wrap the area which accommodates the rear pip-
ing housing section with vinyl tape.
Connection
pipe
Vinyl tape
(wide)
Connecting cable
Vinyl tape(narrow)
• Bundle the piping and drain hose together by
wrapping them with vinyl tape over the range with-
in which they fit into the rear piping housing sec-
tion.
Wrap with vinyl tape
Pipe
Drain hose
40 Multi type Air Conditioner
Indoor unit
drain hose
Vinyl tape(narrow)
Insulation material
Indoor
unit pipe
Wrap with vinyl tape
Pipe
Vinyl tape(wide)
For right rear piping
1. Route the indoor tubing and the drain hose to the
required piping hole position.
2. Insert the piping, drain hose and the connecting
cable into the piping hole.
3. Insert the connecting cable into the indoor unit.
• Don't connect the cable to the indoor unit.
• Make a small loop with the cable for easy connec-
tion later.
4. Tape the drain hose and the connecting cable.
• Connecting cable
5. Indoor unit installation
• Hang the indoor unit from the hooks at the top of
the installation plate.
• Insert the spacer etc. between the indoor unit and
the installation plate and separate the bottom of
the indoor unit from the wall.
Connecting cable
Drain pipe