hit counter script

LG AMNH076LQL0 Service Manual page 34

Multi type
Hide thumbs Also See for AMNH076LQL0:
Table of Contents

Advertisement

Installation
3. Art Cool Deluxe Type Indoor Unit
The wall you select should be strong and solid enough
to prevent vibration
1) Mount the installation plate on the wall with four
type A screws. If mounting the unit on a concrete
wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
Installation Plate
Type "A" screw
2) Measure the wall and mark the centerline. It is
also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi-
cally. Drilling the hole through the wall for piping
connections must be done safely.
(SU)
C
Installation plate
Ø70mm
Left rear piping
(SZ)
Installation plate
C
Left rear piping
CHASSIS
(Grade)
A
SU
92
(9k, 12k)
SZ
35
(7k)
34 Multi type Air Conditioner
A
Ø70mm
Right rear piping
A
Right rear piping
Distance (mm)
B
C
D
44
67
44
33
156
33
3). Drill a hole in the wall
• Drill the piping hole with a ø70mm hole core drill. Drill
the piping hole at either the right or the left with the
hole slightly slanted to the outdoor side.
Indoor
WALL
Outdoor

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents