SNMP Settings

Click on "SNMP" on the left column below HOME.
The SNMP protocol is used to get status information and to control a monitor directly via the network.
Version:
SNMP v1
Authenticated plaintext by community name, does not return a confirmation message of the trap.
SNMP v2c Authenticated plaintext by community name, returns a confirmation message of the trap.
Community name:
The default setting of community name is "public". It is read only. You can set community names for up to 3 settings.
Trap:
Sending error message to a specified address when an error occurs in the monitor.
Check Box
Temperature
Fan
Power
Inverter/Backlight
No Signal
PROOF OF PLAY
System Error
AMX Settings
Click on "AMX" on the left column below HOME.
AMX BEACON
To turn on or off for the detection from AMX Device Discovery when connecting to a network
supported by an AMX's NetLinx control system.
HINT:
When using a device that supports AMX Device Discovery, all AMX NetLinx control systems will
recognize the device and download the appropriate Device Discovery Module from an AMX server.
Selecting [ENABLE] AMX Device Discovery will detect the device.
Selecting [DISABLE] AMX Device Discovery will not detect the device.
CRESTRON Settings
Click on "CRESTRON" on the left column below HOME.
CRESTRON ROOMVIEW compatibility
The monitor supports CRESTRON ROOMVIEW, allowing multiple devices connected in the network to be managed and
controlled from a computer or a controller.
For further information visit
http://www.crestron.com
ROOMVIEW
ROOMVIEW for managing from the computer.
ON: Enables ROOMVIEW.
OFF: Disables ROOMVIEW.
CRESTRON
CRESTRON CONTROL for managing from the controller.
CONTROL
ON: Enables CRESTRON CONTROL.
OFF: Disables CRESTRON CONTROL.
CONTROLLER IP
Sets the IP address of the CRESTRON SERVER.
ADDRESS
IP ID
Sets your CRESTRON SERVER IP ID.
HINT:
The CRESTRON settings are required only for use with CRESTRON ROOMVIEW.
For further information visit
Explanation
Temperature abnormal
Cooling fan abnormal
Power abnormal
Inverter or backlight abnormal 0x90, 0x91
No signal
Lower the log storage
System error
http://www.crestron.com
English-55
Error code
0xA0, 0xA1, 0xA2
0x80, 0x81
0x70, 0x71, 0x72, 0x78
0xB0
0xD0
0xE0