Sleep timer operation

• When the sleep time is reached after [1,2,3,4,5,6,7hr] is input by the remote control during the operation, the
operation of the appliance stops.
• When the appliance is on pause, the sleep timer mode cannot be input.
1. Sleep timer operation for cooling cycle
• While in cooling mode operation, 30 min. later since the start of the sleep timer, the setting temperature
increase by 1°C. After another 30min. elapse, it increases by 1°C again.
Setting temp. (˚C)
Cooling ON temp.
(Setting temp. +0.5˚C)
Cooling OFF temp.
(Setting temp. -0.5˚C)
2. Sleep timer operation for heating cycle
• While in heating mode operation, 60 min. later since the start of the sleep timer, the setting temperature
decrease by 1°C. After another 60min. elapse, it decreases by 1°C again.
Setting temp. (°C)
Heating OFF temp.
(Setting temp. +4°C)
Heating ON temp.
(Setting temp. +2˚C)
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
1.0˚C up
1.0˚C up
Sleep time ( hr )
0.5
1
1.0°C down
1.0°C down