hit counter script

LG LS-J0762YL/NM/NN/NQ Service Manual page 26

Room air conditioner
Table of Contents

Advertisement

3) How to fix installation plate
The wall you select should be strong and solid enough to
prevent vibration
1. Mount the installation plate on the wall with
6 type "A" screws. If mounting the unit on a con-
crete wall, use anchor bolts.
Mount the installation plate horizontally by aligning
the centerline using a level.
Installation Plate
Type "A" screw
2. Measure the wall and mark the centerline. It is also
important to use caution concerning the location
of the installation plate-routing of the wiring to
power outlets is through the walls typically. Drilling
the hole through the wall for piping connections
must be done safely.
C
Installation plate
Ø70mm
Left rear piping
CHASSIS
(Grade)
A
7k, 9k
50
12k, 18k
45
A
Ø70mm
Right rear piping
Distance (mm)
B
C
D
20
80
20
40
80
20
4) Drill a hole in the wall
Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left with
the hole slightly slanted to the outdoor side.
Indoor
-26-
WALL
Outdoor