3) How to fix installation plate
The wall you select should be strong and solid enough to
prevent vibration
1. Mount the installation plate on the wall with
6 type "A" screws. If mounting the unit on a con-
crete wall, use anchor bolts.
Mount the installation plate horizontally by aligning
the centerline using a level.
Installation Plate
Type "A" screw
2. Measure the wall and mark the centerline. It is also
important to use caution concerning the location
of the installation plate-routing of the wiring to
power outlets is through the walls typically. Drilling
the hole through the wall for piping connections
must be done safely.
C
Installation plate
Ø70mm
Left rear piping
CHASSIS
(Grade)
A
7k, 9k
50
12k, 18k
45
A
Ø70mm
Right rear piping
Distance (mm)
B
C
D
20
80
20
40
80
20
4) Drill a hole in the wall
Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left with
the hole slightly slanted to the outdoor side.
Indoor
-26-
WALL
Outdoor