hit counter script

Sleep Timer Operation - LG LS-J0762YL/NM/NN/NQ Service Manual

Room air conditioner
Table of Contents

Advertisement

11. Sleep timer operation

• When the sleep time is reached after [1,2,3,4,5,6,7hr] is input by the remote control during the operation, the
operation of the appliance stops.
• When the appliance is on pause, the sleep timer mode cannot be input.
11.1 Sleep timer operation for cooling cycle
• While in cooling mode operation, 30 min. later since the start of the sleep timer, the setting temperature
increase by 1°C. After another 30min. elapse, it increases by 1°C again.
Setting temp. (˚C)
Cooling ON temp.
(Setting temp. +0.5˚C)
Cooling OFF temp.
(Setting temp. -0.5˚C)
11.2 Sleep timer operation for heating cycle
• While in heating mode operation, 60 min. later since the start of the sleep timer, the setting temperature
decrease by 1°C. After another 60min. elapse, it decreases by 1°C again.
Setting temp. (˚C)
Heating OFF temp.
(Setting temp. +3.0˚C)
Heating ON temp.
(Setting temp)
1.0˚C up
1.0˚C up
Sleep time ( hr )
0.5
1
0.5˚C down
1.0˚C down
1
2