hit counter script

Auto Cleaning; Auto Changeover - LG AS-W096ERH0 Svc Manual

Universal air conditioner
Hide thumbs Also See for AS-W096ERH0:
Table of Contents

Advertisement

Auto Cleaning

• Function used to perform the Self Cleaning to prevent the Unit from Fungus and Bad Odors.
• Used after the Shut Down of Cooling Operation to Clean the Evaporator and keep it as fresh for the Next operation.
• During Self Cleaning the Outdoor Unit is Switched off.
• The function is easy to be operated as It is accessed through the Remote Controller.
1) Heat/pump Model
ON
Cooling CYCLE
Comp.
Indoor Fan
Setting Step

Auto Changeover

• The air conditioner changes the operation
mode automatically to keep indoor tempera-
ture.
• When room temperature vary over ±2°C with
respect to setting temperature, air condition-
er keeps the room temperature in ±2°C with
respect to setting temperature by auto
change mode.
Low Ambient
• If outdoor temperature drops below certain temperature,liquid back is prevented by reducing fan speed.
It can prevent frosting of evaporator and keep cooling operation
• No matter even if the outdoor temperature reaches -10°C.
• You can Cool your room at your desired temperature all your around.
Freq.
On
On
Off
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
OFF
Fan
Heating
13 Min
60 Sec 120 Sec
ON
OFF
ON
Low
Low
Comp Freq.
Outdoor fan
Outdoor pipe temp.
°
0°C outdoor fan On/Off
control
Off
°...
Outdoor temp.
- 0°C
2) Cooling/only Model
ON
Fan
Comp.
OFF
Indoor Fan
Low
Outdoor temp.
Indoor temp.
+ 2°C
+ 1°C
+ 0.5°C
Set Temp.
- 0.5°C
- 1°C
- 2°C
Auto
Change
COOLING
Mode.
25
Cond . temp.
20
15
10
Outdoor fan On/Off control
5
0
0
50
-5
- 37 -
OFF
Cooling CYCLE
Fan
30 Min
ON
OFF
Setting Step
Low
Outdoor
temp.
HEATING
Outdoor temp.:-10°C
100
150
Time(Min.)
LGE Internal Use Only
Operation
30°C
20°C
10°C
200

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Uploaded: cache9/manual/792165/Lg-As-W096erh0.html%3Fpage%3D37.gz