hit counter script

Power Relay Control; Protection From Total Current Control - LG AS-W096ERH0 Svc Manual

Universal air conditioner
Hide thumbs Also See for AS-W096ERH0:
Table of Contents

Advertisement

Operation

Power relay control

• Power relay turns on 1 second later after the power is input to the outdoor unit.
• Control sequence : power on

Protection from total current control

I CT1 control
• If the operating current reaches I1, the operating frequency of the compressor decrease.
• After decreasing the operating frequency by 1step, if operating current is below I1 for 60 seconds continuous-
ly, the operating frequency of compressor increase by 1step.
I CT2 control
• If the operating current of the appliance reaches I2, the compressor stop instantly and 2 minutes later the
compressor restart again.
• If CT2 occurs 5 times within 1hour, the appliance turn off and display ERROR CODE 7.
Control table
Model
1 AS-W096ERH0/BH0/VH0
2 AS-W126ERH0/BH0/VH0
cf. I1 is set the lowest level between intial value and in case dectection of dc paeak current.
Protection from DC Peak Current
I DC Peak Current Error by a fault signal of IPM
• If the operating current of IPM reaches 35A ±3A, the compressor stop instantly.
• If DC PEAK occurs 5 times within 1 hour, the appliance turns off and display ERROR CODE 6.
I DC Peak Current Error by the compressor lock
• If the DC LINK voltage below DC 140V occurs 5 times within 1 hour while the compressor is operating, the
appliance turns off and display ERROR CODE 6.
I DC Peak Current Error by the Outdoor Fan Lock
• If it's 5 times within 1 hour in case of the temperature of outdoor pipe TH is over 65°C while the compressor is
operating, the appliance turns off and display ERROR CODE 6.
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
PTC operating
power relay on
❇ I1:Current of operating frequency down
I2: Current of compressor cut off
Outdoor temp ≥ 38°C
Cooling
Heating
7.0A
8.5A
7.0A
8.5A
- 34 -
I1
Outdoor temp < 38°C
Cooling
Heating
7.5A
9.0A
7.5A
9.0A
I2
10.0A
10.0A
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Uploaded: cache9/manual/792165/Lg-As-W096erh0.html%3Fpage%3D34.gz