GENERAL DATA
Specifications
Table 4: Single Zone Mega 115V System Specifications.
System Model Number (IDU/ODU)
Cooling Capacity (Min/Rated/Max) (Btu/h)
Cooling Power Input
(kW)
1
Heating Capacity (Min/Rated/Max) (Btu/h)
Heating Power Input
(kW)
1
COP
EER
SEER
HSPF
Power Supply (V/Hz/Ø)
Outdoor Unit Operating Range
Cooling (°F DB)
Heating (°F WB)
Indoor Unit Operating Range
Cooling (°F WB)
Heating (°F DB)
Indoor Temperature Setting Range
Cooling (°F)
Heating (°F)
Unit Data
Refrigerant Type
2
Refrigerant Control
IDU Sound Pressure
dB(A) (H/M/L/Sleep)
3
ODU Sound Pressure
dB(A)
3
Unit Weight (lbs)
IDU (Net/Shipping)
ODU (Net/Shipping)
Power/Communication Cable
4
Compressor
Compressor Type (Qty)
Fan
IDU Type (Qty)
ODU Type (Qty)
Motor/Drive
Airflow Rate
IDU Max/H/M/L (CFM)
ODU Max (CFM)
Piping
Liquid Line (in, OD)
Vapor Line (in, OD)
Condensation Line (OD, ID)
Additional Refrigerant Charge (oz/ft)
Pipe Length
(Minimum/Maximum)(ft)
5
Piping Length
(no add'l refrigerant, ft)
5
Max Elevation Difference (ft)
EEV: Electronic Expansion Valve
IDU: Indoor Unit
This unit comes with a dry helium charge.
This data is rated 0 ft above sea level with 24.6 of refrigerant line per indoor unit and a 0 ft level
difference outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 59ºF wet
bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
12 | PRODUCT DATA
LS090HXV2 (LSN090HXV2/LSU090HXV2)
(No. x AWG)
ODU: Outdoor Unit
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG " is a registered trademark of LG Corp.
3,070 ~ 9,000 ~ 10,330
0.732
3,070 ~ 10,900 ~ 12,520
0.875
3.65
12.30
20
10
115/60/1
14 to 118
42 / 36 / 28 / 21
50
19.2 / 22
58.4 / 60
Twin Rotary (1)
Cross Flow (1)
Propeller (1)
Brushless Digitally Controlled/Direct
459 / 353 / 264 / 148
953
1/4
3/8
27/32, 5/8
0.22
9.8 / 49.2
24.6
23
Power Input is rated at high speed.
1
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy R410A
2
refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608 of CAA.
Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
3
All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied
4
and must be a minimum of four-conductor, 14 AWG, stranded, shielded or unshielded (if shielded, it
must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and
national codes. For detailed electrical information, please see the Electrical Data section.
Piping lengths are equivalent.
5
LS120HXV2 (LSN120HXV2/LSU120HXV2)
3,070 ~ 12,000 ~ 13,780
1.142
3,070 ~ 12,000 ~ 13,780
1.000
3.52
10.51
19
9.5
14 to 65
53 to 75
60 to 86
65 to 86
60 to 86
R410A
EEV
42 / 36 / 28 / 21
50
19.2 / 22
58.4 / 60
4 x 14
Twin Rotary (1)
459 / 353 / 264 / 148
953
1/4
3/8
27/32, 5/8
0.22
9.8 / 49.2
24.6
23