PERFORMANCE DATA
Maximum Heating Capacity
Maximum Heating Capacity Table for LS180HEV2 (LSU180HEV2 +
LSN180HEV2)
Table 38: LSN180HEV2 / LSU180HEV2 Heating Capacities.
Outdoor Air
Temp.
60
°F DB °F WB
TC
PI
16
14
14.59
2.08
17
15
15.14
2.10
19
17
15.99
2.11
24
23
17.55
2.12
32
30
19.13
2.05
41
38
20.64
1.91
43
40
21.26
1.82
47
43
22.54
1.75
53
50
22.21
1.70
59
53
21.95
1.67
64
57
22.34
1.62
70
61
22.42
1.55
75
65
22.74
1.39
Maximum Heating Capacity Table for LS240HEV2 (LSU240HEV2 +
LSN240HEV2)
Table 39: LSN240HEV2 / LSU240HEV2 Heating Capacities.
Outdoor Air
Temp.
60
°F DB °F WB
TC
PI
16
14
16.89
2.53
17
15
17.53
2.56
19
17
18.51
2.57
24
23
20.32
2.59
32
30
22.15
2.50
41
38
23.90
2.32
43
40
24.61
2.22
47
43
26.10
2.13
53
50
25.72
2.08
59
53
25.42
2.03
64
57
25.86
1.98
70
61
25.96
1.88
75
65
26.33
1.70
DB: Dry Bulb Temperature (°F)
WB: Wet Bulb Temperature (°F)
PI: Power Input (kW) (includes compressor, indoor fan motor and outdoor fan motor)
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible.
Do not extrapolate.
68 | PERFORMANCE DATA
Indoor Air Temperature (°F DB)
64
68
TC
PI
TC
PI
14.38
2.11
14.17
2.14
14.93
2.13
14.71
2.16
15.77
2.13
15.56
2.15
17.32
2.13
17.09
2.13
18.89
2.06
18.65
2.06
20.39
1.94
20.14
1.98
21.01
1.86
20.75
1.90
22.28
1.81
22.02
1.87
21.93
1.76
21.65
1.82
21.93
1.74
21.91
1.81
21.99
1.65
21.65
1.68
22.02
1.54
21.62
1.54
22.27
1.44
21.80
1.48
Indoor Air Temperature (°F DB)
64
68
TC
PI
TC
PI
16.65
2.57
16.41
2.61
17.28
2.60
17.04
2.63
18.26
2.60
18.01
2.62
20.05
2.59
19.79
2.60
21.87
2.51
21.59
2.51
23.61
2.37
23.32
2.42
24.32
2.26
24.03
2.31
25.80
2.21
25.50
2.29
25.39
2.15
25.06
2.22
25.39
2.12
25.37
2.21
25.47
2.02
25.07
2.05
25.50
1.88
25.03
1.88
25.79
1.75
25.24
1.81
TC: Total Capacity (kBtu/h)
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG " is a registered trademark of LG Corp.
70
72
TC
PI
TC
PI
14.08
2.15
13.66
2.12
14.62
2.17
14.19
2.13
15.27
2.16
14.96
2.11
16.98
2.14
16.31
2.08
18.54
2.06
17.65
2.00
20.03
2.00
18.99
1.91
21.02
1.91
19.55
1.82
23.00
1.90
20.74
1.80
21.71
1.85
20.24
1.73
21.71
1.84
20.51
1.72
21.50
1.70
20.17
1.59
21.43
1.54
20.12
1.45
21.40
1.50
20.26
1.40
70
72
TC
PI
TC
PI
16.30
2.62
15.82
2.58
16.93
2.65
16.43
2.59
17.68
2.64
17.32
2.58
19.67
2.61
18.88
2.54
21.47
2.52
20.44
2.43
23.19
2.44
21.99
2.33
23.90
2.33
22.64
2.22
25.26
2.32
24.01
2.19
25.14
2.25
23.44
2.11
25.14
2.24
23.75
2.10
24.89
2.07
23.36
1.94
24.82
1.88
23.30
1.76
24.78
1.83
23.45
1.71
Capacity as rated: 0 ft. above sea level with 24.6 ft. of refrigerant piping. 0 ft. level difference between
outdoor and indoor units.
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB), and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
75
86
TC
PI
TC
PI
13.09
2.08
10.84
1.92
13.60
2.06
11.22
1.83
14.27
2.05
11.64
1.80
15.39
2.00
12.00
1.73
16.44
1.90
12.11
1.56
17.59
1.78
12.78
1.33
18.07
1.69
13.02
1.22
19.15
1.66
13.78
1.13
18.50
1.56
12.70
0.96
18.62
1.56
12.52
0.97
18.36
1.45
12.40
0.94
18.34
1.32
12.45
0.85
18.44
1.27
12.34
0.78
75
86
TC
PI
TC
PI
15.15
2.53
12.55
2.34
15.75
2.51
12.99
2.23
16.53
2.49
13.48
2.19
17.82
2.44
13.90
2.10
19.03
2.32
14.03
1.90
20.36
2.18
14.79
1.62
20.92
2.06
15.08
1.49
22.17
2.02
15.95
1.38
21.42
1.91
14.70
1.17
21.56
1.90
14.50
1.18
21.26
1.77
14.35
1.15
21.23
1.61
14.42
1.04
21.35
1.55
14.29
0.95