Cooling Capacity Table for LS240HEV2 (LSU240HEV2 + LSN240HEV2)
Table 19: LSN240HEV2 / LSU240HEV2 Cooling Capacities.
Outdoor
Air Temp.
64 / 53
(°F DB)
TC
SHC
PI
14
13.47
9.98 0.85 16.84 10.62 1.01 20.22 11.27 1.16 24.43 12.08 1.36 26.96 12.56 1.48 22.50 13.70 1.20 19.52 14.46 1.02
23
14.46 10.71 0.84 17.40 11.41 1.02 20.33 12.10 1.19 24.00 12.97 1.41 26.20 13.48 1.55 23.06 14.71 1.23 20.96 15.53 1.02
25
14.69 10.88 0.87 17.56 11.55 1.04 20.43 12.23 1.21 24.02 13.07 1.42 26.18 13.57 1.55 23.31 14.87 1.25 21.40 15.73 1.05
30
15.25 11.30 0.93 17.97 11.92 1.09 20.68 12.55 1.25 24.08 13.32 1.44 26.11 13.79 1.56 23.94 15.26 1.30 22.50 16.25 1.13
35
15.82 11.72 0.99 18.38 12.29 1.14 20.94 12.86 1.28 24.13 13.58 1.47 26.05 14.01 1.57 24.58 15.66 1.35 23.60 16.76 1.20
40
16.39 12.14 1.05 18.79 12.66 1.19 21.19 13.18 1.32 24.19 13.83 1.49 25.99 14.22 1.59 25.21 16.05 1.40 24.70 17.27 1.28
45
16.96 12.56 1.12 19.20 13.03 1.24 21.44 13.50 1.36 24.24 14.09 1.51 25.93 14.44 1.60 25.85 16.45 1.45 25.79 17.79 1.35
50
17.52 12.98 1.18 19.61 13.40 1.29 21.69 13.82 1.40 24.30 14.35 1.53 25.86 14.66 1.61 26.48 16.85 1.50 26.89 18.30 1.43
55
18.09 13.40 1.24 20.02 13.77 1.34 21.95 14.14 1.43 24.36 14.60 1.55 25.80 14.88 1.62 27.12 17.24 1.55 27.99 18.82 1.50
60
18.66 13.83 1.31 20.43 14.14 1.39 22.20 14.46 1.47 24.41 14.86 1.57 25.74 15.10 1.64 27.75 17.64 1.60 29.09 19.33 1.58
65
18.49 13.70 1.37 20.17 14.09 1.45 21.85 14.47 1.53 23.95 14.95 1.63 25.21 15.24 1.69 27.21 17.65 1.67 28.55 19.25 1.66
70
18.32 13.58 1.44 19.91 14.03 1.52 21.50 14.48 1.59 23.48 15.05 1.68 24.67 15.39 1.74 26.68 17.66 1.74 28.02 19.17 1.74
75
18.15 13.45 1.51 19.65 13.97 1.58 21.14 14.49 1.65 23.01 15.14 1.74 24.14 15.53 1.79 26.14 17.67 1.81 27.48 19.09 1.82
80
17.98 13.33 1.57 19.39 13.91 1.64 20.79 14.50 1.71 22.55 15.24 1.79 23.60 15.68 1.84 25.61 17.68 1.88 26.94 19.01 1.90
85
17.81 13.20 1.64 19.12 13.86 1.70 20.44 14.51 1.77 22.08 15.33 1.85 23.07 15.83 1.90 25.07 17.69 1.95 26.40 18.93 1.99
90
17.64 13.08 1.71 18.86 13.80 1.77 20.09 14.52 1.83 21.62 15.43 1.90 22.53 15.97 1.95 24.53 17.70 2.02 25.87 18.85 2.07
17.47 12.95 1.77 18.60 13.74 1.83 19.74 14.53 1.89 21.15 15.52 1.96 22.00 16.12 2.00 24.00 17.71 2.09 25.33 18.77 2.15
95
100
17.01 12.61 1.80 18.17 13.44 1.86 19.34 14.27 1.91 20.79 15.30 1.99 21.66 15.92 2.03 23.58 17.43 2.12 24.87 18.43 2.18
105
16.56 12.27 1.83 17.75 13.13 1.88 18.94 14.00 1.94 20.42 15.08 2.02 21.31 15.73 2.06 23.17 17.14 2.15 24.41 18.09 2.21
110
16.10 11.93 1.85 17.32 12.83 1.91 18.54 13.73 1.97 20.06 14.86 2.05 20.97 15.54 2.09 22.76 16.86 2.18 23.95 17.75 2.24
115
15.53 11.50 1.87 16.70 12.38 1.93 17.88 13.26 1.99 19.35 14.36 2.07 20.24 15.01 2.11 21.98 16.29 2.21 23.14 17.15 2.27
118
15.18 11.25 1.89 16.34 12.11 1.95 17.49 12.97 2.01 18.93 14.05 2.08 19.80 14.70 2.13 21.52 15.95 2.22 22.66 16.79 2.28
122
14.72 11.47 1.91 15.84 12.35 1.97 16.97 13.23 2.03 18.37 14.33 2.10 19.21 14.99 2.15 20.87 16.27 2.24 21.98 17.12 2.31
DB: Dry Bulb Temperature (°F)
WB: Wet Bulb Temperature (°F)
SHC: Sensible Capacity (kBtu/h)
PI: Power Input (kW) (includes compressor, indoor fan motor and
outdoor fan motor)
1. All capacities are net, evaporator fan motor heat is deducted.
2. Grey shading indicates reference data. When operating at this temperature, these values can be
different if the system is not running consistently..
Indoor Air Temperature (°F DB / °F WB)
68 / 57
72 / 61
TC
SHC
PI
TC SHC PI
TC: Total Capacity (kBtu/h)
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG " is a registered trademark of LG Corp.
PERFORMANCE DATA
77 / 64
80 / 67
TC SHC PI
TC SHC
3. Direct interpolation is permissible.
Capacity as rated: 0 ft. above sea level with 24.6 ft. of refrigerant piping. 0 ft. level difference between
outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Cooling Capacity
86 / 72
90 / 75
PI
TC SHC
PI
TC SHC PI
Do not extrapolate.