Wiring Diagram for LSU090HSV5, LSU120HSV5
Figure 22: Wiring Diagram for LSU090HSV5, LSU120HSV5 Units.
COMP
.
You need to buy a dedicated circuit separately.
Factory Wiring
Field Wiring
Optional
or Factory installed
* This function can be optional or factory installed depending on the application model.
OUTDOOR UNIT WIRING DIAGRAM
C_PIPE_
D_PIPE
LGMV
AIR
IPM
IPM
*
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
USE COPPER CONDUCTORS ONLY
CN_4WAY
CN_EEV
CN_SUMP_H
CN_CENTRAL
MEZ67657703 Rev.01_100721
CN2
FUSE
250V T12A
BR
AC_L
BL
AC_N
RD
COM
CN1