ACOUSTIC DATA
Outdoor Units
Outdoor Unit Sound Pressure Level Measurement
Figure 14: Outdoor Unit Sound Level Measurement.
Unit : ft. (m)
3.3 ft. (1)
Outdoor Unit Sound Pressure Levels
Table 7: Art Cool Mirror Outdoor Unit Acoustic Data
Sound Pressure Levels (dB[A])
Model
Cooling (Max)
LSU090HSV5
47
LSU120HSV5
47
LSU181HSV5
55
LSU090HSV5/ LSU120HSV5 Cooling and Heating Sound Pressure Diagrams
Figure 15: LSU090/120HSV5 Cooling Sound Pressure Level Diagram.
20 | PRODUCT DATA
Center of
Outdoor Unit
Heating (Max.)
51
51
55
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
• Measurements are taken 3.3 ft away from the front of the unit.
• Sound pressure levels are measured in dB(A) with a tolerance of ±1.
• Data is valid at nominal operation conditions. Operating conditions
are assumed to be standard.
• Reference acoustic pressure 0dB=20μPa
• Sound pressure levels are tested in an anechoic chamber under ISO
Standard 3745, and may be different according to the test condition
or equipment.
• Sound level will vary depending on a range of factors including the
construction (acoustic absorption coefficient) of a particular room in
which the unit was installed.
Figure 16: LSU090/120HSV5 Heating Sound Pressure Level Diagram.