Chapter 7. MK PROGRAMMING

7.2 Programming Examples

If not especially noted, this section explains programming examples in reference with the K7F-HSCA that is
mounted on the system given below.
● System configuration
GM3-
PA2A
7.2.1
Setting
Preset
Preset
Execution condition (CH0)
Preset
Execution condition (CH1)
CH1 Counter Preset Signal
CH0 Counter Preset Signal
K7P-
G3I-
G3Q-
30AS
D22A
RY4A
P00
P01
P02
DMOVP
P U T P
G3F-
G3Q-
HSCA
TR2A
P03
P05
P04
DMOVP
0
D0100
Lower
Upper
Address 0
Address 1
Lower
Upper
P U T P
7 - 5
I/O Word No.
Writing
the
preset
value ' 0000' to the
Buffer Memory.
Preset is executed.
(1 Pulse On)
Value
Writing
the
preset
value ' 100' to the
Buffer Memory.
Preset is executed.
(1 Pulse On)