Chapter 7.
MK PROGRAMMING
• Operation Description
If the start switch is pushed, the turntable rotates as much as the rotation angle set (60˚ ) and
completes drilling.
If the drilling work complete signal turns On, it rotates again 60˚ . If repeating the above operations
has finished six drilling works, all processing will be finished.
• Operation Format
Speed
• Program
00000
start switch
00003
High speed
Low speed
7 - 17
Stop
1 Pulse On
Conversion of the rotation angle
60˚ from BCD type to BIN type
360˚(1 rotation) : 1000pulse=60˚ : x
x =60˚×1000 ÷360
D0003≒166
Preset value = 0
Preset signal complementary junction
Set value = 166
Set signal
OUT1 : set to "="
High speed counter module
operation enable signal : On
Terminal block output enable
signal : On