Chapter 4. FUNCTION BLOCK
4.2.2 The specification of the comparison value(HSC_CMP)
Specifies the reference value, which will be compared with the current value for the corresponding channel
of the High Speed Counter Module.
F u n c t i o n b l o c k
■ I N P U T
REQ : Function block execution request at rising edge.(
BASE : Base location No. for the loaded high speed counting
module.
(GM1 : 0~31, GM2 : 0~7, GM3/4 : 0~3, GM6 : 0)
SLOT : Slot location No. for the loaded high speed counting
module.
(0 ~ 7)
CH
: Specifies the operating channel No.( 0 ~ 1)
PSET : Specifies the preset value setting(0 ~ 16,777,215)
■ OUTPUT
DONE : Turns on when the function block has finished without
error.
The On state is kept until next request.
However, turns off if error occurs during execution of the
function block.
STAT : Indicates the error that occurs during execution of the
function
block.
*1: G3F-HSCA only applicable