Wiring Connection
Open the control box cover and connect the remote control cord and Indoor power wires.
Connection
cord between the
indoor unit and
the outdoor unit
Terminal Block Indoor
1(L)
Connected to indoor unit
1(L)
2(N)
1(L)
2(N)
outdoor unit
Main
1 ,220 240V , 50Hz
Ø
CAUTION
The power cord connected to the outdoor unit
should be complied with the following specifications
(Rubber insulation, type H05RN-F approved by HAR
or SAA).
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer
or its service agent.
WARNING: Make sure that the screws of the terminal are free from
looseness.
Wi r ed Remote
Controller Cord
(there is no need
in case of Wi r eless
Remote Controller)
Control box cover
(On which the Electric
Connection co rd Wiring
Connection is put)
2(N)
3
3
AT-C186PLE0
AT-C186PLE1
AT-C246PLE0
AT-C308PLE0
AT-C368NLE0
AT-C488MLE0
AT-C548MLE0
(R)
(S)
Main
Ø
3 ,380 415V ,50HZ
The connecting cable connected to the indoor and
outdoor unit should be complied with the following
specifications (Rubber insulation, type H05RN-F
approved by HAR or SAA).
2
2.5 mm
Cord, clip
Terminal Block Indoor
1(L)
2(N)
Connected to indoor unit
(T)
(N )
1(L)
2(N)
outdoor unit
AT-C186PLE0
AT-C186PLE1
AT-C246PLE0
AT-C308PLE0
AT-C368NLE0
AT-C488MLE0
AT-C548MLE0
Installation Manual 13
Installation
3
3
4
5
2
0.75 mm