Connection of Piping Indoor
• Preparing the indoor unit's piping and drain hose
for installation through the wall.
• Remove the plastic tubing retainer(see illustration
below) and pull the tubing and drain hose away
from chassis.
• Replace the plastic tubing holder in the original
position.
Tubing holder
CAUTION:
When
install, make sure
that the remaining
parts must be removed
clearly so as not to dam-
age the piping and drain
hose, especially power
cord and connecting cable.
For right rear piping
1. Route the indoor tubing and the drain hose in
the direction of rear right.
Drain hose
2. Insert the connecting cable into the indoor unit
from the outdoor unit through the piping hole.
• Do not connect the cable to the indoor unit.
• Make a small loop with the cable for easy
connection later.
3. Tape the tubing, drain hose, and the connecting
cable. Be sure that the drain hose is located at
the lowest side of the bundle. Locating at the
upper side can cause drain pan to overflow
inside the unit.
Connecting
cable
Drain hose
If the drain hose is routed inside the
NOTICE
room, insulate the hose with an insula-
tion material* so that dripping from
"sweating"(condensation) will not dam-
age furniture or floors.
*Foamed polyethylene or equivalent is recom-
mended.
4. Indoor unit installation
• Hook the indoor unit onto the upper portion of the
installation plate.(Engage the two hooks of the rear
top of the indoor unit with the upper edge of the
installation plate.) Ensure that the hooks are prop-
erly seated on the installation plate by moving it
left and right.
Press the lower left and right sides of the unit against the
installation plate until the hooks engage into their
slots(clicking sound).
4. Connecting the pipings to the indoor unit and
drain hose to drain pipe.
• Align the center of the pipes and sufficiently tight-
en the flare nut by hand.
Indoor unit tubing
Installation
Loop
Gas side
piping
Liquid side
piping
Connecting
cable
Drain hose
Flare nut
Pipes
Service Manual 17