7. When Inlet Grille does not operate.
• Confirm that the Inlet Grille is normally geared with the shaft of Stepping
Motor.
• If the regular torque is detected when moving the Inlet Grille with hands
• Check the connecting condition of CN-SUC Connector
• Check the soldering condition(on PWB) of CN-SUC Connector
• Confirm that there is DC + 12V between pin (RED) of CN-U/D and
GND.
• Confirm that there is a soldering short at following terminals.
- Between
- Between
- Between
• Confirm the assembly conditions that are catching and interfering parts
in the rotation radial of the Inlet Grille
Normal
Check the operating circuit of the Inlet Grille
,
,
and
,
,
and
,
,
and
If there are no problems after above checks
of MICOM
of IC01G
of IC01G
-52-