3) How to fix installation plate
The wall you select should be strong and solid enough
to prevent vibration
1. Mount the installation plate on the wall with four
type A screws. If mounting the unit on a concrete
wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
Installation Plate
Type "A" screw
2. Measure the wall and mark the centerline. It is
also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi-
cally. Drilling the hole through the wall for piping
connections must be done safely.
(SU)
C
Installation plate
Ø70mm
Left rear piping
(SZ)
Installation plate
C
Left rear piping
CHASSIS
(Grade)
A
SU
92
(11k~14k)
SZ
35
(7k~9k)
A
Ø70mm
Right rear piping
A
Right rear piping
Distance (mm)
B
C
D
44
67
44
33
156
33
4) Drill a hole in the wall
• Drill the piping hole with a ø70mm hole core drill. Drill
the piping hole at either the right or the left with the
hole slightly slanted to the outdoor side.
Indoor
-21-
WALL
Outdoor