hit counter script
Table of Contents

Advertisement

5. When up/down Vertical Louver does not operate.
• Confirm that the up/down Vertical Louver is normally geared with the
shaft of Stepping Motor.
• If the regular torque is detected when rotating the up/down Vertical
Louver with hands
• Check the connecting condition of CN-U/D Connector
• Check the soldering condition(on PWB) of CN-U/D Connector
• Confirm that there is DC + 12V between pin (Gray) of CN-U/D and
GND.
• Confirm that there is a soldering short at following terminals.
- Between
- Between
- Between
• Confirm the assembly conditions that are catching and interfering parts
in the rotation radial of the up/down Vertical Louver
Normal
Check the up/down operating circuit of the Vertical Louver
,
,
and
of MICOM
60
61
62
63
,
,
and
of IC01M
,
,
and
of IC01M
If there are no problems after above checks