Electric characteristics
9. Electric characteristics
Model
ASUW093F2B2(LAU090HVP)
ASUW123F2B2(LAU120HVP)
ASUW093MMM9(LSU090HYV)
ASUW123MMM9(LSU120HYV)
ASUW093BRM9(LAU090HSV2)
ASUW123BRM9(LAU120HSV2)
ASUW183CRM9(LAU180HSV2)
ASUW243CRM9(LAU240HSV2)
ASUW093B1Y9(LSU091HSV2)
ASUW123B1Y9(LSU121HSV2)
ASUW183C2Y9(LSU181HSV2)
ASUW243DGY9(LSU240HSV2)
ASUW303DGY9(LSU307HV2)
ASUW363DGY9(LSU360HV2)
Notes :
1. Voltage range
Voltage supplied to the unit terminals should be within the
minimum and maximum range
2. Maximum allowable voltage unbalance between phase is 2 %
3. Select wire spec. based on the larger value of MCA.
4. RLA is measured during each individual compressor test
condition.
5. OFM is measured as the outdoor unit test condition
6. Recommended circuit breaker is ELCB (Earth Leakage circuit
breaker)
48
Unit
Type
Hz
Voltage
Inverter 60
208~230
Inverter Single
Power
Voltage range MCA MOP MSC
10
15
10
15
10
15
10
15
10
15
10
15
19
30
MIN : 187
MAX : 253
19
30
10
15
10
15
19
30
19
30
19
30
19
30
MCA : Minimum Circuit Amperes (A)
MOP : Maximum rating over current protective device.(A)
MSC : Maximum Starting Current)(A)
RLA : Rated Load Amperes (A)
OFM : Outdoor Fan Motor
kW : Fan Motor rated output (kW)
FLA : Full Load Amperes (A)
6RMI0-04C
Compressor
OFM
RLA
kW
FLA
-
7.6
0.08
0.25
-
7.6
0.08
0.25
-
7.6
0.12
1.04
-
7.6
0.12
1.04
-
7.6
0.08
0.45
-
7.6
0.08
0.45
-
14.6
0.12
0.75
-
14.6
0.12
0.75
-
7.6
0.08
0.25
-
7.6
0.08
0.25
-
14.6
0.12
0.25
-
14.6
0.12
0.75
-
14.6
0.12
0.75
-
14.6
0.12
0.75