hit counter script

Indoor Unit - LG LSN090HYV Product Data Book

Hide thumbs Also See for LSN090HYV:
Table of Contents

Advertisement

6RMI0-04C
Select the best Location

Indoor unit

1. There should not be any heat or steam near the unit.
2. Select a place where there are no obstacles around
of the unit.
3. Make sure that condensation drainage can be
conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the left
(or right) of the unit is more than 100mm(3 29/32
inch). The unit should be installed as high as possible
on the wall, allowing a minimum of 200mm(7 29/32
inch) from ceiling.
6. Use a metal detector to locate studs to prevent
unnecessary damage to the wall.
7. Recommended height 1.98m (6.5ft) from the oor.
NOTICE
• Remove obstructions to prevent blockage of air ow path.
Outdoor unit
1. If an awning is built over the unit to prevent direct
sunlight or rain exposure, make sure that heat
radiation from the condenser is not restricted.
2. Ensure that the space around the back and sides is
more than 300mm(11 13/16 inch). The space in front
of the unit should be more than 700mm(27 19/32
inch) of space.
3. Do not place animals and plants in the path of the
warm air.
4. Take the weight of the air conditioner into account
and select a place where noise and vibration are
minimum.
5. Select a place where the warm air and noise from the
air conditioner do not disturb neighbors.
62
minimum distance
to the side : 102(4)
minimum distance
to the side : 508(20)
More than
300(11 13/16)
F e n
c e
o b
o r
s t a
c l e
s
Inverter Single
Installation
minimum distance
to the ceiling : 203(8)
minimum distance
to the side : 102(4)
Unit : mm(inch)
minimum distance
to the ceiling : 203(8)
minimum distance
to the side : 508(20)
Unit : mm(inch)
More than
300(11 13/16)
More than
600(23 19/32)
More than
700(27 19/32)
Unit : mm(inch)

Advertisement

Table of Contents
loading

Table of Contents

Uploaded: cache9/manual/980076/Lg-Lsn090hyv.html%3Fpage%3D63.gz