hit counter script

Shroud; Electrical Parts; Overload Protector; Compressor - LG C6000 Service Manual

Room air conditioner
Table of Contents

Advertisement

Disassembly Instructins

SHROUD

1. Remove the fan. (Refer to section 2.2.2)
2. Remove the shroud. (See Figure 8)
3. Re-install the components by referring to the
removal procedure, above.

Electrical Parts

OVERLOAD PROTECTOR

1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the nut which fastens the terminal cover.
3. Remove the terminal cover. (See Figure 9)
4. Remove all the leads from the overload protector.
5. Remove the overload protector.
6. Re-install the components by referring to the
removal procedure, above.

COMPRESSOR

1. Remove the cabinet. (Refer to section 2.1.2)
2. Discharge the refrigerant system using a Freon
Recovery System.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before venting
the Freon
. Leave the valve in place after
TM
servicing the system.
3. Remove the overload protector. (Refer to section
2.3.1)
4. After purging the unit completely, unbraze the suc-
tion and discharge tubes at the compressor con-
nections.
5. Remove the 3 nuts and the 3 washers which
fasten the compressor.
6. Remove the compressor. (See Figure 10)
7. Re-install the components by referring to the
removal procedure, above.
12 Room Air Conditioner
Figure 8
Figure 9
TM
Figure 10

Advertisement

Table of Contents
loading

Table of Contents

Uploaded: cache9/manual/980032/Lg-C6000.html%3Fpage%3D12.gz