hit counter script

Shroud; Electrical Parts; Overloadprotector; Compressor - LG W081CA Service Manual

Room air conditioner
Hide thumbs Also See for W081CA:
Table of Contents

Advertisement

2.2.3 SHROUD
1. Remove the fan. (Refer to section 2.2.2)
2. Remove the screw which fastens the shroud.
3. Remove the shroud. (See Figure 8)
4. Re-install the component by referring to the
removal procedure, above.
Pi
A
BH
ZE
2
\
X
/
ІШІ
Һ
Ж ШШ
ED
D
тү»,
D
ED
n
E
D
ИБ
D
чү»
MP
ED
Figure 8
2.3 ELECTRICAL PARTS
2.3.1 OVERLOAD PROTECTOR
1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the nut which fastens the terminal cover.
3. Remove the terminal cover. (See Figure 9)
4. Remove all the leads from the overload protector.
5. Remove the overload protector.
6. Re-install the component by referring to the
removal procedure, above.
Figure 9
2.3.2 COMPRESSOR
1. Remove the cabinet. (Refer to section 2.1.2)
2. Discharge the refrigerant system using a Freon™
Recovery System.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before venting
the Freon™. Leave the valve т place after
servicing the system.
3. Remove the overload protector. (Refer to section
2.3.1)
4. After purging the unit completely, unbraze the
suction and discharge tubes at the compressor
connections.
5. Remove the 3 nuts and the 3 washers which
fasten the compressor.
6. Remove the compressor. (See Figure 10)
7. Re-install the components by referring to the
removal procedure, above.

Advertisement

Table of Contents
loading

Table of Contents

Uploaded: cache9/manual/3358524/Lg-W081ca.html%3Fpage%3D12.gz