Specifications - LG ARNU073TUC4 Instruction Manual

Multi v ceiling cassette indoor unit
Table of Contents

Advertisement

GENERAL DATA

Specifications

Type
Cooling Mode Performance
Capacity (Btu/h)
Power Input
(W)
1
Heating Mode Performance
Capacity (Btu/h)
Power Input
(W)
1
Entering Mixed Air
Cooling Max (°F WB)
Heating Min (°F DB)
Unit Data
Refrigerant Type
2
Refrigerant Control
Net Unit Weight (lbs)
Shipping Weight (lbs)
Grille Weight (lbs)
Grille Shipping Weight (lbs)
Communication Cable
3
(No. x AWG)
Fan
Quantity
Airflow Rate H/M/L (CFM)
Piping
Liquid Line (in, OD)
Vapor Line (in, OD)
Condensate Line (in, ID)
Power Input is rated at high speed.
1
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or
2
destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F)
under section 608 of CAA.
All communication cable to be minimum 18 AWG, 2-conductor, stranded, shielded and
3
must comply with applicable local and national codes. Ensure the communication cable
is properly grounded at the master outdoor unit only. Do not ground the ODU−IDU com-
munications cable at any other point.
EEV: Electronic Expansion Valve
Power wiring is field supplied and must comply with the applicable local and national
codes. Power Supply (V/Hz/Ø): 208-230/60/1
14
Table 2: 4-Way Cassette Indoor Units Specifications – continued
4-Way Ceiling Cassette – 3 ft x 3 ft Models – TP, TN, TM Chassis
ARNU243TPC4
ARNU283TPC4
24 200
28 000
33
33
27 300
31 500
33
33
76
76
59
59
R410A
R410A
EEV
EEV
48
48
58
58
13
13
20
20
2 x 18
2 x 18
1
1
600 / 530 / 459
671 / 565 / 494
3/8 Flare
3/8 Flare
5/8 Flare
5/8 Flare
1
1
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
ARNU363TNC4
ARNU423TMC4
36 200
144
40 600
144
76
59
R410A
EEV
54
64
13
20
2 x 18
1
883 / 777 / 706
3/8 Flare
5/8 Flare
1
This unit comes with a dry nitrogen charge.
This data is rated 0 ft above sea level, with 25 ft of refrigerant line per indoor unit and a 0 ft
level difference between outdoor and indoor units. All capacities are net with a combina-
tion ratio between 95-105%.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and
67ºF wet bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and
outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
ARNU483TMC4
42 000
48 100
144
144
43 800
51 200
144
144
76
76
59
59
R410A
R410A
EEV
EEV
59
59
69
69
13
13
20
20
2 x 18
2 x 18
1
1
1059 / 918 / 812
1130 / 953 / 883
3/8 Flare
3/8 Flare
5/8 Flare
5/8 Flare
1
1