Specifications
Nominal 2 Ton
Indoor Unit
System
Outdoor Unit
Decoration Panel
Cooling Capacity
Heating Capacity
Input
Cooling/Heating
Running Current
Cooling/Heating
Power Supply
Power Factor
E.E.R
Cooling
C.O.P
Heating
Setting Temperature Range(cool/heat)
Dehumidification Rate
Refrigerant Control
Refrigerant Charge
Indoor Unit
Output
Model
No. of Poles
Indoor fan motor
Input
Running Current
Capacitor
Type
Indoor Fan
No. Used / Diameter
Cooling(H/M/L)
Indoor Fan RPM
Heating(H/M/L)
Air Circulation
Indoor (H/M/L)
Noise Level
Indoor(H/M/L)
(Sound Press,1m)
Temperature Controller
Tube Size (OD)
Indoor Coil
Fins per inch
No. of Rows & Column
Indoor
Dimensions (W*D*H)
Panel
Net Weight
Indoor
Outdoor Unit
Locked Rotor Amp.
Type
Quantity
Model
Maker
Compressor
Capacity
Motor Type
Motor Input
Oil Type
Oil Charge
O.L.P Type(Model Name)
Tube Size (OD)
Outdoor Coil
Fins per inch
No. of Rows & Column
Output
Model
No. of Poles
Outdoor fan motor
Input
Running Current
Capacitor
Type
No. Used / Diameter
Outdoor Fan
Discharge
Speed
Air Circulation
Outdoor
Noise Level
Outdoor
(Sound Press,1m)
Liquid
SVC Valve
Gas
Dimensions (W * H * D)
Outdoor
Net Weight
Outdoor
Others
Power Supply Cable(With Earth Cable)
Conncecting Cable(With Earth Cable)
Liquid Side
Connecting Tube
Gas Side
(ø. Socket Flare)
Length, std
Max length/elevation
Indoor Unit
Drain hose (ID ø)
Outdoor Unit
Notes: 1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F)WB
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F)WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
2. Capacities are Net Capacities.
3. Due to our policy of innovation some specifications may be changed without notification.
28 Universal System Air Conditioner
ATNH246FLAA, ATNH246FLCA
PT-HFA,PT-HFC
W(kcal/h)
7,034(6,048)
Btu/h
24000
W(kcal/h)
7,767(6,678)
Btu/h
26500
W
2,400/2,380
A
10.7/10.7
ø,V,Hz
1, 220-240, 50
%
93
W/W(kcal/hW)
2.93(2.52)
Btu/hW
10
W/W(kcal/hW)
3.26(2.80)
Btu/hW
11.13
°C
18~30/16~30
l/h
3.3
Capillary Tube
g(oz), type
ATNH246FLAA, ATNH246FLCA
W
40.3
OEM-3502P2
6
W
121
A
0.53
µF/Vac
4.0/ 440
Turbo Fan
EA/mm(inch)
1/382(15)
rpm
600 / 540 / 480
rpm
600 / 540 / 480
CMM(CFM)
15/14/13(530/494/459)
dB(A)±3
43/41/38
Thermistor
inch(mm)
0.275(7)
21
2R 12C
inch(mm)
29.3*29.4*11.5(744*744*292)
inch(mm)
33.5*33.5*1.18(850*850*30)
kg(lbs)
26(57.3)
A
No.
W(Btu/h)
W
cc
inch(mm)
W
W
A
µF/Vac
EA/inch(mm)
Side / Top
rpm
CMM(CFM)
dB(A)±3
inch(mm)
inch(mm)
kg(lbs)
No.* mm
2
inch(mm)
inch(mm)
m
m
mm
mm
ABNH246HLAA
AUUH246A/AB
-
7,034(6,048)
24000
7,854(6,754)
26800
2,400/2,500
10.8/11.2
1, 220-240, 50
95
2.93(2.52)
10
3.14(2.76)
10.72
18~30/16~30
3.3
Capillary Tube
1,900(67.1), R-410A
ABNH246HLAA
118
IC-13450LG13C
4
180
0.92
6/370
Sirocco Fan
2/177(7)
1417/1350/1255
1417/1350/1255
18/16.5/14(636/583/494)
37/35/33
Thermistor
0.275(7)
21
3R 10C
34.6*10.2*17.7 (880*260*450)
-
28(61.7)
AUUH246A/AB
62
Rotary
1
GP290P
LG
6,250(24,800)
PSC
2505
FVC68D
1130
Internal
0.275(7)
18
2R 36C
67.2
IC-28640LG28P
6
120
0.54
6 / 370
Propeller
1/18.1(460)
Side Discharge
850
58(2048)
52
1 / 4 (6.35)
5 / 8 (15.88)
34.2*31.5*12.6(870*800*320)
60(132.2)
3 * 2.5
5 * 0.75
1 / 4 (6.35)
5 / 8 (15.88)
7.5
50/30
ø25
ø32
Heating:- Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Interconnecting Piping Length 7.5 m
- Level Difference of Zero.
Heat Pump
AVNH246BLAA
-
7,034(6,048)
24000
7,737(6,653)
26400
2,330/2,450
10.4/11.0
1, 220-240, 50
93
3.02(2.60)
10.3
3.15(2.71)
10.77
18~30/16~30
3.3
Capillary Tube
AVNH246BLAA
35
IC-9430LGCE
4
63
0.27
1.5/370
Cross Flow Fan
1/80(3.1)
1160/1060/960
1160/1060/960
15/14/13(530/494/459)
45/42/39
Thermistor
0.275(7)
20
2R 14C
47.24*24.21*8.07(1200*615*205)
-
22(48.5)