Functions
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
• Room temperature sensor. (THERMISTOR)
Room temperature control
• Maintains the room temperature in accordance with the Setting Temp.
Starting Current Control
• Indoor fan is delayed for 5 sec at the starting.
Time Delay Safety Control
• Restarting is inhibited for approx. 3 minutes.
Indoor Fan Speed Control
• High, Med, Low
Operation indication Lamps (LED)
On/Off
Timer or
Sleep Mode
Defrost Mode : Lights up during Defrost Mode or Hot
Outdoor unit
operation
Plasma Mode : Lights up during plasma-purification
Soft Dry Operation Mode
• Intermittent operation of fan at low speed.
Sleep Mode Auto Control
• The fan is switched to low(Cooling), med(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
Natural Air Control by CHAOS Logic
• The fan is switched to intermittent or irregular operation
• The fan speed is automatically switched from high to low speed.
Airflow Direction Control
• The louver can be set at the desired position or swing
up and down automatically.
: Lights up during the system operation.
: Lights up during Timer operation or
Sleep mode.
Start operation. (Heat pump model only)
: Lights up during outdoor unit operation.
(Cooling model only)
operation.(option)
Auto Restart Mode
Auto Restart Button : In failure of electric power, if the
Forced Operation Button : Operation starts, when this button
Deice (defrost) control (Heating)
• Both the indoor and outdoor fan
stops during deicing.
Hot-start Control (Heating)
• The indoor fan stops until the
evaporator piping temperature will be
reached at 28°C.
- 3 -
: Lights up during if Restart Button
is pressed.
button is pressed the unit runs as
previous setting operation when
power returns.
is pressed and stops when you
press the button again.