Wiring Diagram - LG LS-M3021CL Service Manual

Room air conditioner
Table of Contents

Advertisement

Wiring Diagram

• 30K, 32K
(1) Indoor Unit
LS- M3060HL/CL/AL/BL, LS-M3061HL/CL/BL/AL
LS- M3064HL/CL/DL/DM/EM, LS-M3063CL
LS- M3221HL/CL/BL/AL, LS-M3021CL/AL
CN-MOTOR
OR
MOTOR
BK
SH-CAPA.
CN-POWER
FUSE
AC250V/T2A
PILLAR
3(L) 4(N) 5
TERMINAL
DISPLAY PCB ASM
TO OUTDOOR UNIT
AUTO RESTART
(2) Outdoor Unit
LS-M3064HL/EM, LS-M306LHL/LEL
START
CAPACITOR
BK
R
BL
S
RD
COMP
C
BR
RUNNING
CAPACITOR
BR
BR
TERMINAL
BR
BLOCK 2
1
2
BR
BL
BR
1(L)
2(N)
POWER INPUT
OUTDOOR WIRING DIAGRAM
LS-M3064CL/DL/DM, LS-M3063CL, LS-M306LCL/LDL
START
CAPACITOR
BK
R
BL
S
RD
COMP
C
BR
RUNNING
CAPACITOR
BR
BR
TERMINAL
BR
BLOCK 2
1
2
BR
BR
1(L)
2(N)
POWER INPUT
OUTDOOR WIRING DIAGRAM
TRIAC
ZNR
THERMISTOR
STEP
MOTOR
(UP/DOWN)
H.V.B ASM
STEP
MOTOR
(L/R)
Negative ion
LIMITS S/W
STEP
MOTOR
(L/R)
OPTION
CN-DISP
FORCED OPERATION
INDOOR WIRING DIAGRAM
3854A20065A
BK
CAPACITOR
YL
OUTDOOR PCB
OR
CN-FAN
FAN
BK
OR
RY-CAPA
BR
BK
CN-COMP1
REVERSING
CN-4WAY
BR
VALVE
CN-COMP2
CN-
CN-
CN-
P2(N)
P1(L)
COMM
POWER
RELAY
BR
BL
BK
BK
BK
BL
3(L)
4(N)
5
TERMINAL BLOCK
TERMINAL
BLOCK1
TO INDOOR UNIT
3854A20051A
BK
CAPACITOR
YL
OUTDOOR PCB
OR
CN-FAN
BK
OR
RY-CAPA
BR
CN-COMP1
BR
CN-COMP2
CN-
CN-
CN-
P2(N)
P1(L)
COMM
POWER
RELAY
BL
BR
BL
BK
BK
BR
BL
3(L)
4(N)
5
TERMINAL BLOCK
TERMINAL
BLOCK1
TO INDOOR UNIT
3854A20051B
(Outdoor Unit - Continued)
LS-M3021AL, LS-M3061CL/AL
COMP
OUTDOOR WIRING DIAGRAM
LS-M3060HL, LS-M3061HL/BL,
LS-M3221HL/BL
COMP
OUTDOOR WIRING DIAGRAM
LS-M3060HL/BL, LS-M3061HL,
LS-M3221CL/AL, LS-M3021CL
FAN
OUTDOOR WIRING DIAGRAM
- 13 -
R
BL
OUTDOOR PCB
S
RD
CN-FAN
C
BR
RUNNING
CAPACITOR
BR
CN-COMP2
CN-
CN-
CN-
P2(N)
P1(L)
COMM
POWER
RELAY
BL
BR
BK
BL
5
1(L)
2(N)
3(L)
4(N)
TERMINAL BLOCK
(COMM)
TERMINAL BLOCK1
POWER INPUT
TO INDOOR UNIT
R
BL
OUTDOOR PCB
S
RD
CN-FAN
C
BR
RUNNING
CAPACITOR
BR
CN-COMP2
CN-4WAY
CN-
CN-
CN-
P2(N)
P1(L)
COMM
POWER
RELAY
BL
BR
BK
BL
5
1(L)
2(N)
3(L)
4(N)
TERMINAL BLOCK
(COMM)
TERMINAL BLOCK1
POWER INPUT
TO INDOOR UNIT
R
BL
OUTDOOR PCB
S
RD
COMP
CN-FAN
C
BR
RUNNING
CAPACITOR
BR
CN-COMP2
CN-
CN-
CN-
P2(N)
P1(L)
COMM
POWER
RELAY
BL
BR
BK
BL
5
1(L)
2(N)
3(L)
4(N)
TERMINAL BLOCK
(COMM)
TERMINAL BLOCK1
POWER INPUT
TO INDOOR UNIT
CAPACITOR
YL
OR
FAN
OR
3854A20051G
CAPACITOR
YL
OR
FAN
OR
BK
REVERSING
VALVE
BK
3854A20051F
CAPACITOR
YL
OR
FAN
OR
3854A20051D