hit counter script

LG LA245HV Installation Manual page 21

Hide thumbs Also See for LA245HV:
Table of Contents

Advertisement

Outdoor
1. Remove the cover control from the unit by
loosening the screw.
Connect the wires to the terminals on the
control board individually as the following.
2. Secure the cable onto the control board with
the holder (clamper).
3. Refix the cover control to the original position
with the screw.
Wiring Diagram
BR
BL
NOTICE
1. Separately wire power supply cord and connecting cable.
2. Use heat-proof electrical wiring capable of withstanding temperature up to 75°C(167°F).
3. Use outdoor and waterproof connection cable rated more than 300V for the connection between
indoor and outdoor unit. (For example, Type SJO-WA)
• Be sure to comply with local codes while running the wire from the indoor unit to the outdoor
unit(size of wire and wiring method, etc).
• Every wire must be connected firmly.
• No wire should be allowed to touch refrigerant tubing, the compressor or any moving parts.
BR
BL RD
Outdoor unit
Terminal block
Over 5mm
(0.2")
Power supply
cord
Cover control
Installation
Conduit panel
Connecting
cable
Installation Manual 21

Advertisement

Table of Contents
loading

Table of Contents

Uploaded: cache9/manual/3524883/Lg-La245hv.html%3Fpage%3D21.gz