• Please read this installation manual completely before installing the product. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only. • Please retain this installation manual for future reference after reading it thoroughly. TYPE : WALL MOUNTED www.lg.com P/NO : MFL59506830...
TIPS FOR SAVING ENERGY TIPS FOR SAVING ENERGY Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below: •...
SAFETY PRECAUTIONS IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product WARNING It can result in serious injury or death when the directions are ignored CAUTION It can result in minor injury or product damage when the directions are ignored WARNING...
Page 4
SAFETY PRECAUTIONS • Do not install the product on a defective installation stand. - It may cause injury, accident, or damage to the product. • Be sure the installation area does not deteriorate with age. - If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
TABLE OF CONTENTS TABLE OF CONTENTS IMPORTANT SAFETY INSTALLATION INSTRUCTIONS Select the best Location Fixing Installation Plate Drill a Hole in the Wall INSTALLATION PARTS Flaring Work - Cut the pipes and the cable INSTALLATION TOOLS - Burrs removal - Putting nut on - Flaring work INSTALLATION MAP - Check...
INSTALLATION PARTS INSTALLATION PARTS Name Quantity Shape Installation plate 1 EA The feature can be changed according a type of model. Type "A" screw 5 EA Type "B" screw 2 EA Type "C" screw 2 EA Remote control 1 EA holder Screws for fixing panels are attached to decoration panel.
INSTALLATION MAP INSTALLATION MAP Installation plate Sleeve Bushing-Sleeve Putty(Gum Type Sealant) Bend the pipe as closely on the wall as possible, but be careful that it doesn't break. Vinyl tape (Wide) • Apply after carrying out a drainage test. • To carry out the drainage test, remove the air filters Saddle and pour water into the heat...
INSTALLATION INSTALLATION Select the best Location Fixing Installation Plate - There should not be any heat or steam near The wall you select should be strong and solid the unit. enough to prevent vibration - Select a place where there are no obstacles Mount the installation plate on the wall around of the unit.
INSTALLATION Drill a Hole in the Wall Burrs removal 1. Completely remove all burrs from the cut - Drill the piping hole with a ø65mm hole core cross section of pipe/tube. drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the 2.
INSTALLATION Pull back the tubing holder. Handle Remove pipe port cover and positioning the tubing Yoke Tubing holder Indoor unit back side view Cone Copper pipe Clamp handle Red arrow mark Right Left Backwards Downwards Check Compare the flared work with the figure * The feature can be changed according a type of model.
INSTALLATION Bad case Installation of Indoor Unit - Following bending case from right to left di- Hook the indoor unit onto the upper por- rectly may cause damage to the tubing. tion of the installation plate.( engage the three hooks at the top of the indoor unit with the upper edge of the installation plate) Ensure that the hooks are properly seated on the installation plate by moving...
INSTALLATION <Right side piping> Connecting the installation pipe and drain hose to the indoor unit. Align the center of the pipes and suffi- ciently tighten the flare nut by hand View Indoor unit tubing Flare nut Pipes Terminal block Tighten the flare nut with a wrench Remote controller cable Outside diameter...
INSTALLATION Wrap the insulation material Finishing the indoor unit around the connecting portion. installation Overlap the connection pipe insulation ma- Mount the tubing holder in the original terial and the indoor unit pipe insulation positon. material. Bind them together with vinyl Ensure that the hooks are properly seated tape so that there may be no gap.
INSTALLATION Checking the Drainage Do not make drain piping like the follow- ing. To check the drainage. Pour a glass of water on the evaporator. Do not raise Ensure the water flows through the drain hose of the indoor unit without any leak- age and goes out the drain exit.
INSTALLATION Installation of filters Test Running Pull out the [Allergy free filter + Triple Fil- - Check that all tubing and wiring are properly ter] from the separately packed plastic bag. connected. Detach the two nitto tapes from the filter. - Check that the gas and liquid side service valves are fully open.