Owner's instruction
Quick Sanitary Tank Heating
If there is urgent sanitary heating demand, Quick Sanitary Tank Heating mode can be used to reduce
the time to reach target sanitary tank temperature by forcibly turning on sanitary tank heater.
After reaching target sanitary tank temperature or by user's input to stop, Quick Sanitary Tank Heat-
ing mode will be finished.
1
Press Sanitary Tanke Heating Enable button with up button for 3 seconds to start Quick
Sanitary Tank Heating. 'Sanitary Tank Heating Enable' icon and 'Sanitary tank heater' icon
will be flashing together.
2
If target sanitary tank temperature is reached or user pushes Sanitary Tanke Heating
Enable button with down button for 3 seconds, Quick Sanitary Tank Heating will be finished
and icon flashing will be stopped.
16 Air-to-Water Heat Pump