THERMA V Split Type General Information 1. Model line up 1.1 Indoor Units Model Name External Heater Capacity Category Type Heating Capacity class* (kW) Appearance [kW] 16.0 AHNW16606A3 [HN1616 NK3] Hydro Box Type AHNW16809A3 [HN1639 NK3] AWHP Split Type DHW Tank AHNW16606B0 Integrated Type [HN1616T NB0]...
Page 5
THERMA V Split Type General Information 2. Nomenclature 2.1 Indoor Unit Global Name Model Name Signification Air-to-Water Heat Pump for R410A Classification N : Indoor unit of Split type U : Outdoor unit of Split type B : Monobloc type Model Type W : Inverter Heat Pump H : Heat Pump...
Page 6
THERMA V Split Type General Information 2. Nomenclature European Name Model Name Signification Air-to-Water Heat Pump for R410A Classification N : Indoor unit of Split type U : Outdoor unit of Split type M : Monobloc type Heating Capacity (kW) Ex) 9kW '09', 12kW '12'...
THERMA V Split Type General Information 2. Nomenclature 2.2 Outdoor Unit Global Name Model Name Signification Air-to-Water Heat Pump for R410A Classification N : Indoor unit U : Outdoor unit : Set Model Type W : Inverter Heat Pump H : Heat Pump Heating Capacity (kW) Ex) 5kW : ‘05’, 16kW : '16' Electrical ratings...
Page 8
THERMA V Split Type General Information 2. Nomenclature European Name Model Name Signification H : Air-to-Water Heat Pump for R410A Classification U : Outdoor unit Heating Capacity (kW) Ex) 5kW : ‘05’, 16kW : '16' Electrical ratings 1 : 1Ø, 220-240V AC 50 Hz 3 : 3Ø, 380-415V AC 50 Hz Classification N : Indoor unit of Split type...
Split Type Indoor Unit THERMA V Hydro Box Unit DHW Tank Integrated Unit...
Page 10
Split Type Hydro Box Unit THERMA V 1.Features 2.List of Functions 3.Specification 4.Dimensions 5.Wiring Diagram 6.Piping Diagram 7.Hydraulic Performance 8.Sound Levels 9.Installation 10.Accessories...
Page 11
THERMA V Split Type Hydro Box Unit 1. Features • Prividing eco-friendly heating • High energy efficiency • Easy installation • Space heating, cooling, and Domestic Hot Water heating...
THERMA V Split Type Hydro Box Unit 2. List of Functions AHNW16606A3 [HN1616 NK3] Category Function AHNW16809A3 [HN1639 NK3] Drain pump E.S.P. control Installation Electric heater(operation) High ceiling operation Hot start Reliability Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock...
THERMA V Split Type Hydro Box Unit 6. Piping Diagram AHNW16606A3 [HN1616 NK3] / AHNW16809A3 [HN1639 NK3] City Water Shower B/HT 3Way V/V2 Solar W/Pump2 Fan Coil Unit W/TANK SOLAR THERMAL 3Way Indoor unit V/V_1 SYSTEM E/HT Radiator Ref. Out 2Way V/V_1 Ref.
Page 20
: Solar panel, Sensors, Thermostats, Interim heat exchanger, SOLAR Water pump, etc. - 3rd party accessory and Field installation THER- MAL (no connector) - To utilized hot water heated by (sold separately) SYSTEM SOLAR THERMAL SYSTEM, end-user must by LG AWHP Solar-Kit.
THERMA V Split Type Hydro Box Unit 7. Hydraulic Performance 7.1 Water Pump Capacity Water volume and pump capacity The water pump is BLDC, so it may be required to change default water pump speed in case of noise by waterflow. In most case, however, it is strongly recommended to set speed as Maximum.
THERMA V Split Type Hydro Box Unit 7. Hydraulic Performance 7.2 Water Volume and Expansion Vessel Pressure Expansion vessel inside Hydro Box Unit is included which is 8 liter capacity with 1 bar pre-pressure. That means, according to the volume-pressure graph, total water volume of 230 liter is supported as default. If total water volume is changed because of installation condition, the pre-pressure should be adjusted to secure proper operation.
THERMA V Split Type Hydro Box Unit 8. Sound levels Sound Power Level Note 1. Data is valid at diffuse field condition. 2. Reference acoustic intensity 0dB = 10E-6μW/m 3. Sound power level is measured on the rated condition in the reverberation rooms. Refer to the Model Specifications for nominal conditions(Power source and Ambient temperature, etc) 4.
THERMA V Split Type Hydro Box Unit 9. Installation 9.1 Water Control 9.1.1 Water quality Water quality should be complied with EN 98/83 EC Directives. Detailed water quality condition can be found in EN 98/83 EC Directives. CAUTION • If the product is installed at existing hydraulic water loop, it is important to clean hydraulic pipes to remove sludge and scale.
THERMA V Split Type Hydro Box Unit 9. Installation 9.2 Water Piping and water Circuit Connection 9.2.1 General considerations • Followings are should be considered before beginning water circuit connection. • Service space should be secured. • Water pipes and connections should be cleaned using water. •...
Page 26
THERMA V Split Type Hydro Box Unit 9. Installation WARNING • Water condensation on the floor While cooling operation, it is very important to keep leaving water temperature higher than 16 . Otherwise, dewcondensation can be occurred on the floor.If floor is in humid environment, do not set leaving water temperature below 18 °C.
Page 27
THERMA V Split Type Hydro Box Unit 9. Installation 9.3 Installation Scenes If is installed with pre-existing boiler, the boiler and THERMA V should not be operated together. If entering water temperature of THERMA V is above 57 °C, the system will stop operation to prevent mechanical damage of the unit.
Page 28
THERMA V Split Type Hydro Box Unit 9. Installation CASE2 : Connecting DHW tank (Under floor loop, Fan coil unit and Radiator) Outdoor Indoor Outdoor Unit Indoor Unit Magnetic Filter (Recommended) Hot water Fan coil unit Floor heating loop Radiator Domestic hot water...
Page 29
THERMA V Split Type Hydro Box Unit 9. Installation 9.4 Water charging For water charging, please follow below procedures. • Step 1 Open all valves of whole water circuit. Supplied water should be charged not only inside the indoor unit, but also in the under floor water circuit, DHW tank circuit, FCU water circuit, and any other water circuitscontrolled by the product.
Page 30
THERMA V Split Type Hydro Box Unit 9. Installation 9.5 Dip switch information Turn off electric power supply before setting DIP switch • Whenever adjusting DIP switch, turn off electric power supply to avoid electric shock. Description Setting Default As Master Role when central controller is equipped As Slave Indoor unit + Outdoor unit...
THERMA V Split Type Hydro Box Unit 9. Installation 9.6 Test Run • Before starting operation, pre-check points are described in this chapter. 9.6.1 Test run flow chart START Check whether the power cable and Operate the unit in cooling mode. communication cable are completely connected Does Test operation start? Is water discharged for...
THERMA V Split Type Hydro Box Unit 9. Installation 9.6.2 Check List before Starting Operation Turn off the power before changing wiring or handling unit. Problem Reason Solution • Setting target • Set target temperature correctly. temperature is not • Check if temperature is water-based or air-based. proper.
THERMA V Split Type Hydro Box Unit 9. Installation 9.6.3 Maintenance To assure best performance of THERMA V, it is required to perform periodical check and maintenance. It isrecommended to proceed following check list for once a year. Turn off the power before proceeding maintenance Category Item Check Point...
THERMA V Split Type Hydro Box Unit 10. Accessories 10.1 Dry Contact (PDRYCB500) 10.1.1 Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the followingindications.
THERMA V Split Type Hydro Box Unit 10. Accessories 10.1.3 Name of each part Front Case Rear Case ISO View Side Side Cable(1 EA) Installation Manual (For Connecting with indoor unit) Modbus Gateway For Indoor Unit 1. CN-OUT : Indoor Unit Connector 2.
THERMA V Split Type Hydro Box Unit 10. Accessories 10.1.4 Installation Inside of the indoor unit 1. Loosen and remove two screws that secure the product. 2. Loosen two screws that secure the PCB to separate rear of the case from the PCB. 3.
THERMA V Split Type Hydro Box Unit 10. Accessories Setting Address Address 1 Address 2 Address 3 Address 4 Address 5 Address 6 In case, connect a Modbus controller with several product, Address have to be set different from others. Address 7 Address 8 •...
THERMA V Split Type Hydro Box Unit 10. Accessories 10.2 Remote Temperature Sensor (PQRSTA0) 10.2.1 Part Description Remote temperature sensor can be installed any place a user wants to detect the temperature. Remote Sensor Remote Sensor Connection Wire Parts Connection wire Fixing screw for Installation Manual 15m(1EA)
THERMA V Split Type Hydro Box Unit 10. Accessories 10.2.2 Installation Method How to use 1. After deciding where the remote temperature sensor is installed, decide the location and height of the fixing screws. (Interval between the screws : 60mm) Fixing screws 60mm 2.
Page 40
THERMA V Split Type Hydro Box Unit 10. Accessories 10.3 DHW Tank Kit (PHLTA) 10.3.1 Part Description DHW Tank Kit must be used for communication of DHW tank and indoor unit. It’s for communication with the DHW tank which has electric heater. Sensor (Thermister) : This sensor (RHRSTA0) can be supplied separately.
Page 41
THERMA V Split Type Hydro Box Unit 10. Accessories 10.4 Solar Thermal Kit (PHLLA / PHLLB) 10.4.1 Model Solar Thermal Kit Must be used for communication of solar thermal component and indoor unit. - PHLLA : Sensorʼs limit temperature 100 - PHLLB : Sensorʼs limit temperature 120 10.4.2 Part Description Sensor (Thermister)
Page 42
THERMA V Split Type Hydro Box Unit 10. Accessories 10.5 Drain Pan (PHDPB) 10.5.1 Part Description WARNING 1. Turn the main power off when cleaning, maintaining or installing drain pump. • There is risk of electric shock. CAUTION 1. Do not insert hands or other objects through the air inlet or outlet while the product is operated. •...
THERMA V Split Type Hydro Box Unit 10. Accessories 10.5.2 Installation WARNING 1. Do not Install, remove, or re-install the unit by yourself (customer). • There is risk of fire, electric shock, explosion, or injury. 2. For installation, always contact the dealer or an Authorized Service Center. •...
Page 44
THERMA V Split Type Hydro Box Unit 10. Accessories CAUTION • Take care that drain pan is broken by sharp edge. • Power cable must not go through the knock-out. 8. Assemble the Drain pan (a). 7. Assemble the front panel. - And then connect the drain hose (field supply) to the Drain pan (a).
Page 45
THERMA V Split Type Hydro Box Unit 10. Accessories 10.5.3 Attention 1. Four pipes (two refrigerant pipes and two waterpipes) should be fastened to the Drain Pan (b)with ties. 2. The drain hose (field supply) should be wrappedby thermal insulator (field supply) with minimum10 mm thickness.
Page 46
Split Type DHW Tank Integrated Unit THERMA V 1.Features 2.List of functions 3.Specification 4.Drawing 5.Wiring Diagrams 6.Piping Diagrams 7.Performance Data 8.Water Pump Capacity 9.Installation 10.Accessories...
Page 47
THERMA V Split Type DHW Tank Integrated Unit 1. Features • Providing Eco-friendly heating • High energy efficiency – Pressure Control & Quick Operating Response • Quiet operation • All in one solution – Hydro Box for Space heating/cooling + Domestic How Water Tank + Buffer Tank –...
THERMA V Split Type DHW Tank Integrated Unit 2. List of Functions List of functions AHNW16606B0 Category Functions [HN1616T NB0] Electric heater Installation Domestic Hot Water Tank heater (Install Kit) Screed Drying Mode Reliability Self diagnosis Auto Restart operation Child lock Sleep mode Convenience...
THERMA V Split Type DHW Tank Integrated Unit 3. Specifications Technical Specifications Indoor Unit Model Name AHNW16606B0 [HN1616T NB0] For Fan Coil Unit °C 7 ~ 25 Cooling Operation (Min.~Max.) For under floor °C 7 ~ 25 Range Heating For Fan Coil Unit /Radiator °C 25 ~ 58...
THERMA V Split Type DHW Tank Integrated Unit 3. Specifications Electrical Specifications Indoor Unit Model Name AHNW16606B0 [HN1616T NB0] Power Supply V, Ø, Hz 230, 1, 50 Power Cable (Included Earth)1) No. × mm² 3C × 4.0 (H07RN-F) L1,N,Earth Power connection wiring Heater Type Sheath...
Page 51
THERMA V Split Type DHW Tank Integrated Unit 4. Drawing AHNW16606B0 [HN1616T NB0]...
THERMA V Split Type DHW Tank Integrated Unit 5. Wiring diagrams AHNW16606B0 [HN1616T NB0]...
Page 53
THERMA V Split Type DHW Tank Integrated Unit 5. Wiring diagrams Connecting Elements mark Description Terminals A : Indoor unit Controller Basic input/output module MD1 Communication with I/O module MD2 Communication with the control electronics of the PLC screen module Set-up of bridges (without) Connecting terminal for communication with expansion module MD2 A+, B-...
Page 54
THERMA V Split Type DHW Tank Integrated Unit 5. Wiring diagrams Indoor unit Controller...
Page 55
THERMA V Split Type DHW Tank Integrated Unit 5. Wiring diagrams Element Connecting Terminals Description Marks L1, L2, L3, N, PE Power cable A5, GND Temperature sensor for external temperature Q11, N Cooling valve Q12, N, PE Additional external source Q7, N, PE Circulation pump of heating cycle 1 (optional) Q8, N, PE...
THERMA V Split Type DHW Tank Integrated Unit 6. Piping diagrams DHW Tank Integrated Unit Basic installation (IDU + ODU) Indoor Unit TANK (Optional) 3Way Valve Electric Heater Water Pump 1 : Ball valve 2 : Pressure reducing valve 3 : Check valve Buffer Tank 4 : Safety valve...
Page 57
THERMA V Split Type DHW Tank Integrated Unit 7. Performance Data 7.1 Domestic Hot Water Volume Water Volume means amount of water that can be tapped with a temperature of 40 when the DHW tank has been heated up to a indicated temperature. AHUW096A3 [HU091 U43] AHUW16*A3 [HU16* U33] AHUW14*A3 [HU14* U33]...
Page 58
THERMA V Split Type DHW Tank Integrated Unit 7. Performance Data 7.2 Domestic Hot Water Performance AHUW096A3 [HU091 U43] AHUW16*A3 [HU16* U33] AHUW14*A3 [HU14* U33] AHUW12*A3 [HU12* U33] Tank temperature [ ˚C] Note • Heat up time means time required to heat up the water in tank starting from a temperature of 10 up to the indicated temperature.
Page 59
THERMA V Split Type DHW Tank Integrated Unit 8. Water Pump Capacity The water pump is three speed-adjustable (Maximum / Medium / Minimum), but Minimum step is not used. It is recommended to use Maximum or Medium steps. In case of noise by water flow, it may be required to change default water pump speed.
THERMA V Split Type DHW Tank Integrated Unit 9. Installation 9.1 Water Control 9.1.1 Water quality Water quality should be complied with EN 98/83 EC Directives. Detailed water quality condition can be found in EN 98/83 EC Directives. CAUTION • If the product is installed at existing hydraulic water loop, it is important to clean hydraulic pipes to remove sludge and scale.
THERMA V Split Type DHW Tank Integrated Unit 9. Installation 9.2 Water Piping and water Circuit Connection 9.2.1 General considerations • Followings are should be considered before beginning water circuit connection. • Service space should be secured. • Water pipes and connections should be cleaned using water. •...
Page 62
THERMA V Split Type DHW Tank Integrated Unit 9. Installation WARNING • Water condensation on the floor While cooling operation, it is very important to keep leaving water temperature higher than 16 . Otherwise, dewcondensation can be occurred on the floor.If floor is in humid environment, do not set leaving water temperature below 18 °C.
Page 63
THERMA V Split Type DHW Tank Integrated Unit 9. Installation 9.3 Installation Scenes If is installed with pre-existing boiler, the boiler and THERMA V should not be operated together. If entering water temperature of THERMA V is above 57 °C, the system will stop operation to prevent mechanical damage of the unit.
Page 64
THERMA V Split Type DHW Tank Integrated Unit 9. Installation CASE2 : Connecting Solar thermal system Domestic Hot water Outdoor Indoor City water Outdoor Unit Indoor Unit Magnetic Filter (Recommended) Solar heat source Fan coil unit Floor heating loop Radiator Buffer tank...
Page 65
THERMA V Split Type DHW Tank Integrated Unit 10. Accessories 10.1 Modbus Converter (PP485B00K) 10.1.1 Part Description 1 2 3 4 5 6 7 8 Modbus Gateway For Indoor Unit • LED01G, 02G, 03G: Communication Status LED • LED1:RS-485 Status LED •...
THERMA V Split Type DHW Tank Integrated Unit 10. Accessories Accessory Part List Multi-V 1 2 3 4 5 6 7 8 PP485B00K BRACKET (1EA) SCREW (4EA) Multi Multi-V WIRE ASSY 1(1EA) WIRE ASSY 2(1EA) WIRE ASSY 3(1EA) Others : Tie Wrap (3 EA) - Cable Tie Clamp (1 EA) 10.1.2 Installation Guide Connect CN_OUT with Outdoor Unit by the cable(provided).
Page 67
Split Type Outdoor unit THERMA V 1.List of functions 2.Specification 3.Dimensions 4.Wiring Diagram 5.Piping Diagram 6.Performance Data 7.Operation Range 8.Electric Characteristics 9.Sound Levels 10.Installation...
Page 68
THERMA V Split Type Outdoor unit 1. List of functions List of functions AHUW056A3 [HU051 U43] AHUW126A3 [HU121 U33] AHUW128A3 [HU123 U33] Category AHUW076A3 [HU071 U43] AHUW146A3 [HU141 U33] AHUW148A3 [HU143 U33] AHUW096A3 [HU091 U43] AHUW166A3 [HU161 U33] AHUW168A3 [HU163 U33] Defrost / Deicing High pressure switch Low pressure switch...
Page 69
THERMA V Split Type Outdoor unit 2. Specifications 2.1 Nominal Capacity and Power Input Combination with Hydro Box type Outdoor Unit AHUW056A3 [HU051 U43] AHUW076A3 [HU071 U43] Model Names Indoor Unit AHNW16606A3 [HN1616 NK3] AHNW16606A3 [HN1616 NK3] Cooling Capacity (Rated) Heating Cooling 1.09...
Page 70
THERMA V Split Type Outdoor unit 2. Specifications Outdoor Unit AHUW128A3 [HU123 U33] AHUW148A3 [HU143 U33] Model Names Indoor Unit AHNW16809A3 [HN1639 NK3] AHNW16809A3 [HN1639 NK3] Cooling 10.4 12.0 Capacity (Rated) Heating 12.0 14.0 Cooling 2.60 3.08 Power Input (Rated) Heating 2.64 3.18...
Page 71
THERMA V Split Type Outdoor unit 2. Specifications Combination with DHW tank Integrated type Outdoor Unit AHUW096A3 [HU091 U43] AHUW126A3 [HU121 U33] Model Names Indoor Unit AHNW16606B0 [HN1616T NB0] AHNW16606B0 [HN1616T NB0] Cooling 10.4 Capacity (Rated) Heating 12.0 Cooling 2.88 3.30 Power Input (Rated)
Page 72
THERMA V Split Type Outdoor unit 2. Specifications 2.2 Outdoor Unit Specifications Outdoor Units AHUW056A3 [HU051 U43] AHUW076A3 [HU071 U43] Cooling Min. ~ Max. °C DB 5 ~ 48 5 ~ 48 Operation Range Heating Min. ~ Max. °C DB -20 ~ 35 -20 ~ 35 (Outdoor Tempera-...
Page 73
THERMA V Split Type Outdoor unit 2. Specifications Outdoor Units AHUW096A3 [HU091 U43] AHUW126A3 [HU121 U33] Cooling Min. ~ Max. °C DB 5 ~ 48 5 ~ 48 Operation Range Heating Min. ~ Max. °C DB -20 ~ 35 -20 ~ 35 (Outdoor Tempera- Domestic Hot ture)
Page 74
THERMA V Split Type Outdoor unit 2. Specifications Outdoor Units AHUW146A3 [HU141 U33] AHUW166A3 [HU161 U33] Cooling Min. ~ Max. °C DB 5 ~ 48 5 ~ 48 Operation Range Heating Min. ~ Max. °C DB -20 ~ 35 -20 ~ 35 (Outdoor Tempera- Domestic Hot ture)
Page 75
THERMA V Split Type Outdoor unit 2. Specifications Outdoor Units AHUW128A3 [HU123 U33] AHUW148A3 [HU143 U33] Cooling Min. ~ Max. °C DB 5 ~ 48 5 ~ 48 Operation Range Heating Min. ~ Max. °C DB -20 ~ 35 -20 ~ 35 (Outdoor Tempera- Domestic Hot ture)
Page 76
THERMA V Split Type Outdoor unit 2. Specifications Outdoor Units AHUW168A3 [HU163 U33] Cooling Min. ~ Max. °C DB 5 ~ 48 Operation Range Heating Min. ~ Max. °C DB -20 ~ 35 (Outdoor Tempera- Domestic Hot ture) Min. ~ Max. °C DB Water Type...
Page 77
THERMA V Split Type Outdoor unit 3. Dimensions AHUW056A3 [HU051 U43], AHUW076A3 [HU071 U43], AHUW096A3 [HU091 U43]...
Page 78
THERMA V Split Type Outdoor unit 3. Dimensions AHUW146A3 [HU141 U33], AHUW166A3 [HU161 U33], AHUW128A3 [HU123 U33], AHUW148A3 [HU143 U33], AHUW168A3 [HU163 U33], AHUW126A3 [HU121 U33]...
Page 79
THERMA V Split Type Outdoor unit 4. Wiring Diagrams AHUW056A3 [HU051 U43], AHUW076A3 [HU071 U43], AHUW096A3 [HU091 U43]...
Page 80
THERMA V Split Type Outdoor unit 4. Wiring Diagrams AHUW126A3 [HU121 U33], AHUW146A3 [HU141 U33], AHUW166A3 [HU161 U33]...
Page 81
THERMA V Split Type Outdoor unit 4. Wiring Diagrams AHUW128A3 [HU123 U33], AHUW148A3 [HU143 U33], AHUW168A3 [HU163 U33]...
Page 82
THERMA V Split Type Outdoor unit 5. Piping Diagram LIQUID SIDE Service Indoor Unit Valve Plate Heat (3 way) Exchanger Water. Out Outdoor Unit Heat Exchanger Water. In Pressure 4 way Sensor Valve GAS SIDE Service (Accessories) Valve (3 way) Accumulator Compressor ...
Page 83
THERMA V Split Type Outdoor unit 6. Performance Data 6.1 Cooling Operation 6.1.1 Combination with Hydro Box type AHUW056A3 [HU051 U43] + AHNW16606A3 [HN1616 NK3] Outdoor LWT 7°C LWT 10°C LWT 13°C LWT 15°C LWT 18°C LWT 20°C LWT 22°C Temperature 3.65 0.67...
THERMA V Split Type Outdoor unit 7. Operation Range Cooling Cooling (Fan coil unit) (Under floor) Leaving Water Temperature( Leaving Water Temperature( Continuous Operation Continuous Operation Operative Operative Heating Leaving Water Temperature( Continuous Operation Operative...
THERMA V Split Type Outdoor unit 8. Electric characteristics Wiring of Main Power Supply and Equipment Capacity 1. Use a separate power supply for the Outdoor Unit and Indoor Unit. 2. Bear in mind ambient conditions (ambient temperature,direct sunlight, rain liquid,etc.) when proceeding with the wiring and connections 3.
Page 104
THERMA V Split Type Outdoor unit 8. Electric characteristics Outdoor Unit and Hydro Box Unit Power Supply Model Power Supply for Heater for Heat Pump Back-up Heater DHW Tank Heater Circuit Breaker (A) Phase Circuit Breaker Back-up Indoor Unit Outdoor Unit Volts Back-up Capacity...
Page 105
THERMA V Split Type Outdoor unit 8. Electric characteristics DHW Tank integrated Unit Power Supply Model for Electric Heater Phase Combination of Circuit Breaker Electric Heater Indoor Unit Volts Capacity (kW) Power (kW) 220-240V 1~ 230V 50Hz 16.0 50Hz AHNW16606B0 2.0+2.0 220-240V 1~ 230V 50Hz...
Page 106
THERMA V Split Type Outdoor unit 9. Sound Levels Note 1. Data is valid at diffuse field condition. 2. Reference acoustic intensity 0dB = 10E-6μW/m 3. Sound power level is measured on the rated condition in the reverberation rooms. Refer to the Model Specifications for nominal conditions(Power source and Ambient temperature, etc) 4.
THERMA V Split Type Outdoor unit 10. Installation 10.1 Alternative Refrigerant R410A • The refrigerant R410A has the property of higher operating pressure in comparison with R22. Therefore, all materials have the characteristics of higher resisting pressure than R22 ones and this characteristic should be also considered during the installation.R410A is an azeotrope of R32 and R125 mixed at 50:50, so the ozone depletion potential (ODP) of R410A is 0.
THERMA V Split Type Outdoor unit 10. Installation • When installing the unit in a place that is constantly exposed to a strong wind like a coast or on a high story of a building, secure a normal fan operation by using a duct or a wind shield. 1.
Page 109
THERMA V Split Type Outdoor unit 10. Installation 10.4 Lifting Method • When carrying the suspended unit, pass the ropes under the unit and use the two suspension points each at the front and rear. • Always lift the unit with ropes attached at four points so that impact is not applied to the unit. •...
THERMA V Split Type Outdoor unit 10. Installation 10.5 Installation of outdoor units 10.5.1 Foundation for Installation • Check the strength and level of the installation ground so that the unit will not cause any operating vibration ornoise after installation. •...
THERMA V Split Type Outdoor unit 10. Installation operation time for evacuation varies with tubing length and capacity of the pump. The following table shows the time required for evacuation. Required time for evacuation when 30 gal/h vacuum pump is used If tubing length is less than 10 m(33 ft) If tubing length is longer than 10 m(33 ft) 30 min.
Page 112
THERMA V Split Type Outdoor unit 10. Installation 10.6 Electrical Wiring 10.6.1 Caution 1. Follow ordinance of your governmental organization for technical standard related to electrical equipment, wiring regulations and guidance of each electric power company. WARNING • Be sure to have authorized electrical engineers do the electric work using special circuits in accordance with regulations and this installation manual.
Page 113
THERMA V Split Type Outdoor unit 10. Installation Power Cable Specification The power cord connected to the outdoor unit should be complied with IEC 60245 or HD 22.4 S4 (Rubber insulated cord, type 60245 IEC 66 or H07RN-F) If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Page 114
THERMA V Split Type Outdoor unit 10. Installation 10.6.2 Wiring Procedure for Power Cable and Connecting Cable 1. Disassemble the side panel from the outdoor unit by loosing screws. 2. Connect Power cable to Main Power Terminal and Connecting cable to Control Terminal, respectively. See below figure for detailed information.