Weather-dependent Operation
This mode is only applied to heating.
In order to save energy and to give highest comfort, setting temperature will follow outside tempera-
ture. If outdoor temperature decreases, heating capacity for the house will increase automatically in
order to keep same room temperature. All parameters will be set by installer during start-up proce-
dure and will be adapted to the site characteristic.
1
Press OPER MODE Button to select Weather-dependent operation mode.
: Weather Dependent
operation icon
2
Adjust the desired temperature level by pressing Change Temperature buttons.
View Temperature
Press repeatedly View Tempera-
1
ture Button to select each Tem-
perature.
(Whenever press View Tempera-
ture button, the room tempera-
ture will be displayed during 5
seconds.)
Temperature
Air
Water
( * : Solar Thermal Temperature)
Ex) Decreasing temperature profile by 3°C
Temperature Range
below 11
11 ~ 39
above 39
below 0(*below 40)
0 ~ 92(*40~120)
above 92(*above 120)
Owner's instruction
(based on room air temperature)
< Temperature adjust step (unit :°C) >
-5, -4, -3, -2, -1, 0, 1, 2, 3, 4, 5
Cold
Hot
: View Room Temperature
: View Inlet Temperature
: View Outlet Temperature
: View Sanitary Water Temperature
(ONLY displayed when sanitary
water heating mode)
: View Solar Thermal Temperature
(ONLY displayed when sanitary
water heating mode)
Displayed as
Lo
actual temperature
Hi
Lo
actual temperature
Hi
Owner's Manual 13