14. Installation
CAUTION: Provide a circuit breaker
between power source and the unit as
shown below.
CAUTION: The power cord connected to the outdoor unit should be complied with the fol-
lowing specifications (Cable type approved by HAR or SAA).
NORMAL CROSS
SECTIONAL AREA
Cable Type
The power connecting cable connected to the indoor and outdoor unit should be com-
plied with the following specifications (Type "B" approved by HAR or SAA).
Connecting the cable to the Outdoor unit.
1. Remove the control cover from the unit by loosening
the screw.
Connect the wires to the terminals on the control
board individually as the following.
2. Secure the cable onto the control board with the
holder (clamper).
3. Refix the control cover to the original position with
the screw.
4. Use a recongnized circuit breaker between the
power source and the unit. A disconnection device
to adequately disconnect all supply lines must be fit-
ted.
Circuit
Breaker
(A)
Get user manuals:
See SafeManuals.com
Grade
18k
24k
30k
2.5
2.5
3.5
H05RN-F H05RN-F H05RN-F H05RN-F
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
H05VV-F
Grade (Btu/h)
14k
18k/21k
30k
15
20
30
Main power source
Air
Conditioner
(mm
)
2
40k
5.5
2
Outdoor unit
Terminal block
Over 5mm
Holder for
power supply
cord
Cover control
Connecting
cable
Power cord
Loosen terminal screw
Circuit Breaker
Use a circuit breaker
or time delay fuse.
Terminal block