hit counter script

Ventilation Requirements; Figure 33: Distances For Buried Installation - NEC FA Series User Manual

Led wall bundle fine pitch led video display indoor
Hide thumbs Also See for FA Series:
Table of Contents

Advertisement

3.6 Ventilation Requirements

Caution!
Risk of fire, injuries and product damage due to overheating of the system.
 Ensure proper ventilation and air flow around the system.
 Never block the ventilation spaces around the LED Wall. Keep them free at all
times.
 Never install the system air-tight into an alcove. Always leave the required
minimum ventilation space.
Notice
For installation conditions deviating from the information given below, more calculations
regarding the air flow and cooling of the system are necessary. If you have questions, please
contact NEC DISPLAY SOLUTIONS, see 1.2 Service & Support in Europe.
Minimum Ventilation Spaces for Buried Installation (in Wall Alcove)

Figure 33: Distances for Buried Installation

A
min distance to
min. distance to
sides
top and bottom
60 mm
60 mm
B
C
Distance between
wall and system
30 mm
D
min. distance to
min. distance to
ceiling
floor
500 mm
700 mm
© NEC Corporation 2019
E
32

Advertisement

Table of Contents
loading

Table of Contents

Uploaded: cache9/manual/1873931/Nec-Fa-Series.html%3Fpage%3D32.gz