I.
Centering
Horizontal
a)
BACK RASTER CENTERIN'G
Readjust back
( Adjust
by
CT connector on the)
raster centering
OEF PWB PWE-173A
See Alignment procedure
NG
b)
PICTURE CENTERING
Readjust sub H
Centering
NG
(
See Alignment procedure
)
V R503-VR505 on the OEF PWB
PWE-173A
Check H FlY converter
and
associated circuit
NG
I C504, TR522, Z0504
"
0513,0517,0518, C537
R573, R577, R592
Failure
H F/V converter and
associated circuit
O K . . - - - - - - - - - - - - - - - - - . . . . .
Failure
IC501, IC552
Failure
-51-
(See item F)