FU2-40
LCD display
0
No
1
All
2
Rs + Lsigma
3
Enc Test
4
Tr
☞ Note 1: Ls and Noload-Curr are only valid during Motor
Rotation mode.
☞ Note 2: The motor constants values change with
temperature change, so auto tuning is to be conducted
after the temperature of the motor is stabilized.
☞ Note 3: The auto-tuning result could be different unless
LG motor is used.
☞ Note 4: The actual motor parameters (Rs, Rr, Lsigma,
Tr) can be used or set by user.
Code
LCD display
No Load
FU2-
Noload-Curr
34
Current
(RMS)
FU2-
Auto tuning
Auto Tuning
40
FU2-
Stator
Rs
41
resistance
FU2-
Leakage
Lsigma
42
inductance
FU2-
Stator
Ls
43
inductance
FU2-
Tr
44
constant
[Keypad display during Auto-tuning of motor parameters]
Display
Code
LED
7-Seg.
T1
Rs Tuning
T2
Lsigma
Tuning
FU2-
T3
40
Ls Tuning
T4
ENC Test
T5
Tr Tuning
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
Description
Auto-tuning disabled
Auto-tuning all
parameters
Stator resistance (Rs)
and Leakage inductance
(Lsigma) Auto- tuning
PG status check
Rotor constant(Tr)
calculation
Name
Description
Setting and display the
Motor
No Load Motor Current
(RMS)
Auto-tuning enable
Setting and display the
Stator resistance Rs
Setting and display the
Lsigma
Setting and display the
Stator inductance Ls
Rotor
Setting and display the
Rotor constant Tr.
Description
Displayed during Stator
resistance (Rs) Auto- tuning
Displayed during Leakage
inductance (Lsigma) auto-
tuning.
Displayed during Stator
inductance (Ls) and No-load
current auto- tuning.
Displayed during Encoder auto-
tuning.
Displayed during Rotor filter
time constant (Tr) auto- tuning
Chapter 6 - Parameter Description [FU2]
[Keypad error display after Encoder test]
Display
Code
LED
7-Segment
Enc Err
FU2-
40
Enc Rev
[Motor parameter display corresponding to inverter
capacity]
inverter
Class
capacity
0.8[kW] ~
5.5[kW]
200V
7.5[kW] ~ 55[kW]
0.8[kW] ~
1.5[kW]
400V
2.2[kW] ~ 15[kW]
18.5[kW] ~
75[kW]
☞ Note: For 7-segment Keypad, parameter unit is not
displayed.
Related Functions:
FU2-30~37 [Motor related parameters]
FU2-39 [Control mode selection]
EXT-01 [Sub Board Type Display]
EXT-14 [Encoder Feedback Frequency]
EXT-15 [Pulse Input Signal Selection
FU2-45: P Gain for Sensorless Control
FU2-46: I Gain for Sensorless Control
FU2? SL P-gain
45
1000
Factory Default:
1000
SL P-gain is the proportional gain of speed controller. If
this value is set high, you can get fast speed response
characteristic. However, if this value is set too high, the
steady state characteristics may become unstable.
FU2? SL I-gain
46
100
Factory Default:
100
SL I-gain is the integral gain of speed controller. If this
value is set low, you can get better transient response
characteristic and steady state characteristic . However,
if this value is set too low, there may be an overshoot in
speed control.
109
Description
T6
Displayed when incorrect
Encoder wiring error occurs
T7
Displayed when Encoder
wiring is connected reversly.
Motor parameter
Rs
Lsigma
Ls
Tr
X.XXX
X.XX
X.XX
ohm
mH
mH
X.X
X.XXX
X.XX
mohm
mH
mH
X.XX
X.X mH
X. mH
ohm
X.XXX
X.XX
X.X mH
ohm
mH
X.X
X.XXX
X.XX
mohm
mH
]
45
1000
1000
46
100
100
XXX
ms
XXX
ms
XXX
ms
XXX
ms
XXX
ms