hit counter script

Other Precautions - LG SV-iS5 Instruction Manual

Variable frequency drives
Hide thumbs Also See for SV-iS5:
Table of Contents

Advertisement

1.4 Other Precautions

Do not carry the inverter by the front cover.
l
Do not install the inverter in a location where excessive vibration is present. Be cautious when installing on
l
presses or moving equipment.
The life span of the inverter is greatly affected by the ambient temperature. Install in a location where temperature
l
are within permissible limits (- 10 ~ 40 ℃).
The inverter operates at high-temperatures - install on a non-combustible surface.
l
Do not install the inverter in high-temperature or high-humidity locations.
l
Do not install the inverter in a location where oil mist, combustible gas, or dust is present. Install the inverter in a
l
clean location or in an enclosed panel, free of foreign substance.
When installing the inverter inside a panel with multiple inverters or a ventilation fan, use caution.
l
If installed incorrectly, the ambient temperature may exceed specified limits.
Panel
Inverter
Inverter
Cooling fan
GOOD (O)
[When installing several inverters in a panel]
Install the inverter using screws or bolts to insure the inverter is firmly fastened.
l
UL Remark (File number: E124949):
"Only intended for use in an enclosure with maximum surrounding air temperature of 45℃" or
equivalent: Models SV022iS5-2/4, SV037iS5-2/4, SV055iS5-4 (not -2), SV075iS5-4 (not -2),
SV110iS5-2/4, SV150iS5-2/4, SV185iS5-2/4 and SV220iS5-2/4.
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
Panel
Ventilating fan
Inverter
Inverter
BAD (X)
7
Chapter 1 – Installation
GOOD (O)
[When installing a ventilating fan in a panel]
BAD (X)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF
Uploaded: cache9/manual/1198099/Lg-Sv-Is5.html%3Fpage%3D13.gz