Sign In
Upload
Manuals
Brands
Honeywell Manuals
Control Panel
3-144
User Manuals: Honeywell 3-144 Alarm Control Panel
Manuals and User Guides for Honeywell 3-144 Alarm Control Panel. We have
3
Honeywell 3-144 Alarm Control Panel manuals available for free PDF download: Programming Manual, Installation Manual, User Manual
Honeywell 3-144 Programming Manual (214 pages)
Brand:
Honeywell
| Category:
Security System
| Size: 1.2 MB
Table of Contents
Table of Contents
3
Section 1: Quick Setup
7
Section 2: System Operation
9
Menu Options
9
General
9
The Full Menu
9
The Quick Menu
9
Menu Access
9
Direct Access
10
Menu Driven Access
10
Keypad Menu Timeout
10
Engineer Mode
10
Accessing Engineer Mode
11
Exiting from Engineer Mode
11
Multi User Access
12
Section 3: Setting Options
13
Setting the System Using a PIN
13
Full Setting
13
Part Setting
13
Cancelling the Setting
13
Unsetting the System Using a PIN
14
Engineer Unsetting
14
Keyswitch Setting Options
14
Setting the System with a Keyswitch
14
Unsetting the System with a Keyswitch
14
Setting the System with Cards/Tags/Fobs
14
Unsetting the System with Proximity Cards
15
Cancelling and Resetting Alarms and Alerts
15
Resetting Using Alarm Cause Code
16
Overriding of Faults and Tampers
16
Setting Features
16
Show Set Status
16
Exit Time
17
Exit Time Reset
17
Omitted Zones
17
Expiry Warning
17
System Set Indication
17
Group Logic Setting Restriction
17
Entry Time
18
Timeout (Slow Entry)
18
Straying from the Entry Route
18
Abort Time
18
Abort Setting Message
18
Fail to Set
18
Power Failure While System Is Set
18
Section 4: Menu Options 11-19
19
Option 11 - Omit Zones (Quick Menu Option 0)
19
Option 12 - Timed Set
21
Option 13 - Part Set
21
Option 14 - Forced Set (Quick Menu Option 1)
21
Option 15 - Chime (Quick Menu Option 2)
21
Option 16 - Instant Set
21
Option 17 - Silent Part
22
Option 18 - Home Set
22
Option 19 - All Set
22
Section 5: Display Options
23
Option 21 - Display Zones (Quick Menu Option 3)
23
Option 22 - Display Log (Quick Menu Option 4)
24
Option 23 - System
25
Option 24 - Print (Quick Menu Option 5)
26
Option 25 - Access Doors
27
Section 6: Test Options
31
Option 31 - Walk Test (Quick Menu Option 6)
31
Option 32 - Outputs
32
Section 7: Modify Options
33
Option 41 - Time/Date (Quick Menu Option 7)
33
Option 42 - Codes (Quick Menu Option 8)
34
Default Codes
35
Engineer Code
35
ATM User Codes
35
Escaping from Engineer Mode
36
Programming Codes
37
Option 43 - Summer (Quick Menu Option 9)
45
Option 44 - Trace
45
Option 45 - Timer Control
46
Option 46 - Group Omit
49
Option 47 - Remote Access
50
Option 48 - Access Authorization
56
Section 8: Engineer 1
57
Option 51 - Parameters
57
Assigning Parameters to Groups
57
Option 52 - Program Zones
76
Selecting Zones
76
Attributes
76
System Alarms
80
Option 53 - Program Outputs
92
Selecting Outputs
92
Attributes
93
Output Functions
96
Option 54 - Links
107
Programming Links
107
Option 55 - Soak
110
Programming Soak Zones
110
Option 56 - Communications
111
Internal Telecoms
112
External RS232 Interface Module
124
ISDN Module
126
Ethernet Module
134
Ext Telecoms
145
Int RS232 Port
146
Option 57 - System Print
149
Selecting a Print Option
149
Option 58 - Keypad
150
Option 59 - Quick Menu
153
Section 9: Engineer 2
154
Option 61 - Diagnostics
154
Option 62 - Full Test
157
Option 63 - Options
158
Option 64 - Assemble Zone
168
Programming a Custom Zone
168
Option 65 - Timers
172
Timer a and B
173
Autoset
174
Option 66 - Pre-Checks
178
Testing Zones
178
Option 67 - Remote Reset
179
Option 68 - Menu Access
180
Section 10: Engineer 3
181
Option 71 - SPI Key
181
Fitting the SPI Key
181
Using the SPI Key
182
Removing the SPI Key
183
Appendix A: Library
185
Appendix B: SIA and Contact ID Event Codes
189
Appendix C: SIA Event Structure
201
Appendix D: Event Log Messages
203
Appendix E: Site Data Storage
209
Preparing for Storage Mode
209
Enabling Storage Mode
209
Using Storage Mode
210
Leaving Storage Mode
210
Index
211
Advertisement
Honeywell 3-144 Installation Manual (90 pages)
Brand:
Honeywell
| Category:
Control Panel
| Size: 0.79 MB
Table of Contents
Table of Contents
3
Introduction
7
Variants
7
Section 1: Quick Setup
9
Section 2: System Architecture
11
PCB Layout
14
RS485 Expansion Module (G3-520 Only)
15
System Installation and Wiring
16
Connecting the Galaxy 3 Series to the PSTN
17
Connecting Additional Telecom Apparatus
18
Line Monitoring
18
Stand-By Battery
19
Battery Start-Up
19
On-Board Power Supply Unit
19
Memory
20
RS485 Data Communication Bus (AB Lines)
20
RS485 Wiring Configurations
20
RS485 Wiring Recommendations
21
Zones
23
Zone Addresses
23
Zone Addressing with Onboard RIO Switch
24
Wiring Zones
24
Wiring Multiple Zones
25
Wiring Keyswitches
25
Wiring Terminator Buttons
26
Outputs
26
Output Applications
27
SPI Header
28
Section 3: Optional Modules and Facilities
29
Remote Input Output (RIO) Modules - C072
29
Addressing
29
Connecting the RIO
30
Configuring the RIO
30
Outputs
31
Entry/Exit RIO
31
Entry/Exit RIO
32
Entry/Exit RIO Zone Programming
32
Entry/Exit RIO Zone Operation
32
Slave RIO
32
Rf Rio - C076
33
Connecting the RF RIO
33
Addressing the RF RIO
34
Address Ranges
34
RF RIO Programming
35
Configuring the RF RIO
35
Output Module - C078
36
Addressing
36
Connecting the Output Module
37
Configuring the Output Module
37
Outputs
37
Configuration Jumpers
38
Relay Module
39
Technical Specification - Output Module
39
Technical Specification - Relay Module
39
Power Supply Unit
40
Configuration
40
Installation Instructions
41
Battery
42
Battery Test
42
Specifications
42
EN50131 Compliance
42
Printer Interface Module-A134/A161
43
Telecom Module - E062
44
Connection to the PSTN
44
Programming the Telecom Module
44
RS232 Interface Module - E054
45
Interface with a PC
45
Serial Printer Interface
46
ISDN Module - E077
47
Programming the ISDN Module
47
Ethernet Module - E080
48
Configuring the Ethernet Module
48
Ethernet Communication
48
Remote Servicing Suite
49
Event Monitoring
49
Galaxy Gold
49
User Management Suite
49
Section 4: the Galaxy Mk7 Keypad/Keyprox
51
General
51
Power Consumption
51
Wiring the Keypad/Keyprox
52
Addressing
52
Keypad/Keyprox Installation Procedure
52
Volume Control
54
Adding a Keypad/Keyprox to the System
54
Removing a Keypad/Keyprox from the System
54
Self Diagnostics
55
Keypad/Keyprox Operation
55
Number Keys
55
View Keys
55
Enter Key
55
Escape Key
56
Hash Key
56
Star Key
56
Power LED
57
Display
57
The Galaxy Keyprox
58
General
58
Addressing
58
Operation
58
Card Types
58
Section 5: Door Control Module - MAX3
59
Introduction
59
Standalone
59
On-Line
59
Installing the MAX3
59
MAX3 Pack
59
Mounting the MAX3
59
Wiring the MAX3
60
Configuring as On-Line MAX3
61
Configuring as a Stand-Alone MAX3
62
Removing a MAX3 Reader from the System
63
On-Line Mode
63
Operating Instructions
63
Card-Held Function
63
Card-Held System Setting
63
MAX3 Log
64
Dual Access Cards
65
Dual Focus (Card Held)
65
Timed Anti-Passback
65
Appendix A : Door Control - MAX (MX01
67
Installation Instructions
67
Wiring the MAX
67
Mounting the MAX
68
Surface Mounting the MAX
68
Flush Mounting the MAX
68
Configuring a MAX Reader into the System
69
Configuring as a Stand-Alone MAX
69
Configuring as On-Line MAX
70
Removing a MAX Reader from the System
71
Stand Alone Mode
71
On-Line Mode
71
Programming Instructions for On-Line Readers
71
Operating Instructions (On-Line Modes
72
Gaining Access
72
Card-Held Function
72
Max Log
73
Max Events Print-Out
73
Appendix B: 3 Ampere Smart PSU - P015
75
Grounding
75
Appendix C: Panel Comparisons
77
Appendix D: Declaration of Conformity
79
Compliance and Approvals
79
EN50131 Compliance
80
PD6662 Compliance
80
Public Switched Telephone Network (PSTN) Approval
80
Appendix E: Specifications
81
Panel Specifications
81
Appendix F: Parts List Index
85
Index
87
Honeywell 3-144 User Manual (44 pages)
Galaxy 3 Series alarm system
Brand:
Honeywell
| Category:
Security System
| Size: 0.27 MB
Table of Contents
User Guide
1
Table of Contents
3
Table of Contents
7
Compliance and Approvals
7
Introduction
7
Keypad Information
9
General
9
Number Keys (0 - 9)
9
View Keys (a and B)
9
Enter Key (Ent)
10
Escape Key (Esc)
10
Hash Key (#)
10
Star Key (*)
10
Power LED
10
Banner
10
User Codes
10
Setting the System
11
Before Setting
11
Entering a Pin - User Type 2.1 - 2.2
11
Entering a Pin - User Type 2.3 - 3.6
11
Setting Groups
11
Exit Time
11
Sounder
12
Zones Open
12
Final Door/Terminator
12
System Set
12
Part Setting
12
Cancelling the Setting
12
Group Name
12
Max Setting Options
13
Setting with User Cards/Tags/Fobs
13
Dual Focus
13
Keyprox
13
Unsetting the System
14
Normal Entry
14
Straying from the Entry Route
14
Slow Entry
14
Cancelling Alarms
14
Manager Reset
14
Engineer Reset
14
Unsetting with the MAX Cards
14
Alert Conditions
15
Menu Options
16
Full Menu
16
Quick Menu
16
Accessing the Menu
17
Full Menu
17
Quick Menu
17
Omit Zones (User Type 2.3 and Above)
18
Purpose
18
Selecting Omit Zones
18
Viewing Eligible Zones
18
Omitting Zones
18
Setting with Omitted Zones
18
Vibration Zones
18
Atm 1/2/3/4 Zones
19
Forced Set (User Type 2.3 and Above)
19
Purpose
19
Selecting Forced Set
19
Non-Omittable Zones
19
Chime (User Type 2.3 and Above)
20
Purpose
20
Selecting Chime
20
Chime in Operation
20
Display Zones (User Type 2.4 and Above)
20
Selecting Display Zones
20
Address
20
Function
20
Status
21
Description
21
Selecting and Viewing
21
Escape
21
Display Log (User Type 2.4 and Above)
21
Purpose
21
Selecting Display Log
21
Events
21
Selecting a Date
21
Viewing each Event
21
Additional Information
22
Printing
22
Print (User Type 2.4 and Above)
22
Purpose
22
Selecting Print
22
Codes
22
Zones
22
Log
22
All
22
Help Message
22
Walk Test (User Type 2.5 and Above)
23
Purpose
23
Selecting Walk Test
23
All Zones
23
Selected Zones
23
Ending Walk Test
23
Time/Date (User Type 3.6)
24
Purpose
24
Selecting Time/Date
24
Changing Time
24
Changing Date
24
Advance and Retard
24
Codes (User Type 3.6)
25
Purpose
25
Manager Code
25
Selecting Codes
26
User Codes
26
Modify Pin
26
Modify Type
27
Modify Name
28
Time Zone
28
Temporary Codes
29
Pin Change
29
Modify Groups
30
Max Number
31
Max Function
32
Max Keypad
32
Forgive Antipassback
32
Pin Warning
33
Summer (User Type 3.6)
33
Trace (User Type 3.6)
34
Timer Control (User Type 3.6)
34
Group Omit (User Type 3.6)
37
Remote Access (User Type 3.6)
38
Authorisation Access (User Type 3.6)
39
Avoiding False Alarms
40
Zone Reference Tables
41
Alarm and Help Messages
42
Alarm in Progress
42
Pa Reset Required
42
Manager Reset Required
42
Engineer Reset Required
42
No Entries
42
Invalid Selection
42
Invalid Code
42
Technistore Reset
42
No Modules Added
42
Installer Details
43
Advertisement
Advertisement
Related Products
Honeywell Galaxy 3-48C
Honeywell 3-144C
Honeywell 3114D
Honeywell 3118D
Honeywell 3132D
Honeywell 3100 Series
Honeywell 3100U Series
Honeywell 3106 Series
Honeywell 3150 Series
Honeywell 3153 Series
Honeywell Categories
Thermostat
Controller
Control Unit
Security Camera
Accessories
More Honeywell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL