Hide thumbs Also See for LAN091CNP, LAU091CNP, LAN121CNP:
Table of Contents

Advertisement

The phenomena in case of connecting error
INDOOR UNIT
Connector Type
CN-DC/DC
Blue
Black
Brown
Red
CN-MOTOR
CN-UP/DOWN
CN-DISP
CN-TH
Condition
Open and connecting error
Open
Open
Short between terminals
Open
Open
Short between terminals
(
and
) of ROOM-TH.
Short between terminals
(
and
) of PIPE-TH.
Phenomena
• The same as the phenomenon of Outdoor Unit.
• The indoor fan does not operate.
• The operation indicator of Indoor unit blinks 8 times.
• The up/down vane does not operate.
• The up/down vane does not smoothly operate.
• It does not operate with a remote controller.
• The operation indicator blinks once.
On for 0.5 second
Off for 3 seconds
• The compressor and the outdoor fan stop.
• The indoor fan speed is low.
• The operation indicator blinks once
(on for 0.5 second, off for 3 seconds).
• The compressor operates continuously regardless
of the setting temperature and the variation of room
temperature.
• The operation indicator blinks once
(on for 0.5 second, off for 3 seconds)
• Continuous operation
Troubleshooting Guide