website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html Universal System Air Conditioner SERVICE MANUAL CAUTION • BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. • ONLY FOR AUTHORIZED SERVICE PERSONNEL.
Ceiling & Floor .....................128 V. Functional Description Ceiling Cassette Type..................130 Ceiling Duct Type....................132 Ceiling & Floor .....................135 Outdoor Units ......................138 VII. Explode View and Replacement Parts List Indoor Units ......................151 Outdoor Units ......................169 Panel Assembly, Front ..................179 2 Universal System Air Conditioner...
Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury.
Page 4
• There is risk of fire or electrical • There is risk of fire or electric • There is risk of fire, failure of the shock. shock. product, or electric shock. 4 Universal System Air Conditioner...
Page 5
Safety Precautions Do not store or use flammable gas or com- If strange sounds, or small or smoke comes bustibles near the product. from product. Turn the breaker off or discon- nect the power supply cable. • There is risk of fire or failure of product. •...
Page 6
(outdoor units) the air inlet or outlet while the product is oper- ated. • There is risk of personal injury and failure of product. • There are sharp and moving parts that could cause personal injury. 6 Universal System Air Conditioner...
Introduction • Model Number Nomenclature Indoor unit A T N H 1 8 6 E L F B Serial Number Functions A : Basic B : Low Ambient C : Plasma Filter E : Elevation Grille F : Elevation Grille + Plasma Filter H : Plasma Filter + Low Ambient L : Nano Plasma M : Nano Plasma + Elevation Grille...
Ceiling Cassette 4-way 1. Features & Benefits Convenience • Auto elevation grille(Accessory) • Tele control(Optional) • LCD wired remote control • Group control • Central control(Accessory) • Weekly progam Cleanness • Plasma air purifying system • Hygienic and easy to clean filter Easy Installation •...
Page 12
- It provides you ease of control. Air conditioner can be switched on/off by the telephone. It saves time & energy. In Advance by Telephone In case of Going out Before Coming Home... Without Turning off the Air Conditioner... 12 Universal System Air Conditioner...
Ceiling Cassette 4-way Child Lock Function -It prevents the children or others from tampering with the control buttons. Unit can be controlled by the wireless remote controller. This can be easily set by pressing timer key & Min key simultaneously. After child lock is set, pressing any key will display CL on the LCD for 3 seconds and all the keys will be ineffective.
Central Room.For Setting Temperature, Fan Speed and other sub functions, access the respec- tive LCD wired remote controller of each unit. Sub PI485(with wire assembly) should be pur- Controller Controller Controller chased as optional. 14 Universal System Air Conditioner...
Ceiling Cassette 4-way 2. List of Functions Category Function ATNH-EL ATNH-FL ATNH-DL Air supply outlet Airflow direction control (left & right) Airflow direction control (up & down) Auto Auto Auto Auto swing (left & right) Auto swing (up & down) Air flow Airflow steps(Fan / Cool / Heat) 3/4/3...
- Level Difference of Zero. 2. Cooling/heating capacity of indoor unit can be lower when it is connected to MPS variable outdoor. 3. Wiring cable size must comply with the applicable local and national code. 16 Universal System Air Conditioner...
570 Unit size Unit:mm (unit : mm) Number Name Descripition Liquid pipe connection ø6.35 flare Gas pipe connection 12k: ø9.52, 18k: ø12.7 flare Drain pipe connection Power supply connection Air discharge grille Air suction grille 18 Universal System Air Conditioner...
Page 19
Ceiling Cassette 4-way ATNH-FL(Decoration Panel : PT-HFA, PT-HFC) 790 (Ceiling opening) 572(Hanging bolt) 744 Unit size Unit:mm (unit : mm) Number Name Descripition Liquid pipe connection ø6.35 flare Gas pipe connection 24K: ø12.7, 30K: ø15.88 flare Drain pipe connection Power supply connection Air discharge grille Air suction grille Service Manual 19...
Page 20
840 Unit size Unit:mm (unit : mm) Number Name Descripition Liquid pipe connection 36k:ø6.35, 48/60k: ø9.52 flare Gas pipe connection 36k:ø15.88, 48/60k: ø19.05flare Drain pipe connection Power supply connection Air discharge grille Air suction grille 20 Universal System Air Conditioner...
Ceiling Cassette 4-way 7. Operating Instructions Name and Function of Remote Controller AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Room Temp Heat Pump Model AUTO Heater Preheat Defrost Humidify Filter Out door 1 2 3 4 Time ZONE Operation unit Program set Timer...
Page 24
• Do not place the remote controller in a location exposed to direct sunlight, or near the heating unit, or any other heat source. • Block a strong light over the signal receptor with a curtain or etc. so as to prevent the abnormal operation. (ex:elec- tronic quick start, ELBA, inverter type fluorescent lamp) 24 Universal System Air Conditioner...
Ceiling Cassette 4-way 8. Installation • Please read this instruction sheet completely before installing the product. • When the power cord is damaged, replacement work shall be performed by authorized personnel only. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Anti-bacteria filter Intake Air Outlet...
2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated. 3. Avoid places where inflammable gas is generated. 4. Avoid place where noxious gas is generated. 5. Avoid places near high frequency generators. 26 Universal System Air Conditioner...
Ceiling Cassette 4-way Ceiling Keep the length of the bolt Hanging bolt from the bracket to 40mm (W3/8 or M10) Flat washer for M10 Air Conditioner body (W3/8 or M10) (accessory) Ceiling board Ceiling board Spring washer (M10) Flat washer for M10 (accessory) Set screw of Paper pattern...
Air conditioner Cool air leakage causes sweating. Cool air leakage unit (no good) Water drops fall. Ceiling Ceiling board board Decoration Decoration panel panel Fit the insulator (this part) and be careful for cool air leakage 28 Universal System Air Conditioner...
Ceiling Cassette 4-way 8.5 Indoor Unit Drain Piping Upward Pipe clamp routing • Drain piping must have down-slope (1/50 to 1/100): be sure not allowed not to provide up-and-down slope to prevent reversal flow. Indoor unit • During drain piping connection, be careful not to exert extra force on the drain port on the indoor unit.
• Battery : 2EA control function • Screw : 2EA • Central control Central control Simple PQCSA101S0 • Installation manual • PCB: 1EA PI485 Gateway For central control PHNFP14A0 • Installation manual • Wire assembly 30 Universal System Air Conditioner...
Advanced airflow system and cross flow fan give quiet and more comfortable environment. Noise Distribution(dBA) Vertical Airflow & Balanced Temperature Upward Distribution The heat distribution graph shows an example of even tem- perature distribution achieved by the auto-swing airflow. Downward 32 Universal System Air Conditioner...
Ceiling & Floor 2. List of Functions Category Function AVNH-EL AVNH-BL Air supply outlet Airflow direction control (left & right) Manual Manual Airflow direction control (up & down) Auto Auto swing (left & right) Auto swing (up & down) Air flow Airflow steps(Fan / Cool / Heat) 3 / 4 / 3 3 / 4 / 3...
- Level Difference of Zero. 2. Cooling/heating capacity of indoor unit can be lower when it is connected to MPS variable outdoor. 3. Wiring cable size must comply with the applicable local and national code. 34 Universal System Air Conditioner...
Ceiling & Floor 4. Dimensional Drawings AVNH-EL Signal receiver & Operation indicator Air discharge grille (Unit: mm) Note: 1. Pipe Specification(mm) Model Liquid Ø 6.35 Ø 9.52 Air suction grille <Ceiling Installation> <Floor Installation> More than 20Cm More than 20Cm More than 20Cm More than 5Cm More than 5Cm...
Page 36
Ø 6.35 Ø 15.88 More than 20cm 20cm More than 20cm More than 20cm More than eye-level (Ceiling installation) (Floor/Wall installation) 1076 Suspension bolt (W3/8 or M10) Center-line for the piping hole 1236 1 2 3 36 Universal System Air Conditioner...
Ceiling & Floor 7. Operating Instructions Remote Control Operation The Remote Controller transmits the signals to the system. 1. START/STOP BUTTON Operation starts when this button is pressed and stops when Signal transmitter the button is pressed again. 2. OPERATION MODE SELECTION BUTTON Used to select the operation mode.
• Insulation materials 5.5kg·m ......Gas side piping Spanner ........Half union • Specified Torque Wrenches 1.8kg·m......Liquid side piping 5.5kg·m......Gas side piping • Hexagonal Wrench (4mm) • Gas-leak Detector • Two type “B” screws • Owner’s Manual • Thermometer 40 Universal System Air Conditioner...
Page 41
Ceiling & Floor 8.1 Selection of the best location More than 20cm • There should not be any heat source or steam near the More than 20cm unit. • There should not be any obstacles to the air circulation. More than eye-level •...
Page 42
• The unit must be horizontal or declined to the drain hose connected when finished installation. Ceiling Drain hose Ceiling Side of view • The unit must be declined to the bottomside of the unit when finished installation. Ceiling 42 Universal System Air Conditioner...
Page 43
Ceiling & Floor CAUTION After the confirmation of the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power specially for the air conditioner. As for the method of wiring, be guided by the circuit diagram pasted on the inside of control box cover. 2) Provide a circuit breaker switch between power source and the unit.
Optional Accessories(For Unit) Item Type Model No. Component Parts • Central control Central control Simple PQCSA101S0 • Installation manual • PCB: 1EA PI485 Gateway For central control PHNFP14A0 • Installation manual • Wire assembly 44 Universal System Air Conditioner...
Low Noise ! Easy Serviceability! Plastic Fan and Housing Assembly - Designed for low noise - Designed to reduce weight - Designed for easy service This product guarantees lower sound level and gives lesser service expenses. 46 Universal System Air Conditioner...
Page 47
Ceiling Concealed Duct LG’s High Technology provide Easy and Low cost Design of Duct work Generally, when External Static Pressure increases air volume decreases. But by controlling the phase of motor while installing the product E.S.P. is controlled from 8~10 mmAq linearly. E.S.P. control provides required constant air volume irrespective of ESP change.
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. • **: For ceiling concealed duct model, auto-run function of dry contact is not applicable. If RF remote control use, auto-run function of dry contact is applicable. (Refer to accessory PDB) 48 Universal System Air Conditioner...
Ceiling Concealed Duct 3. Specifications Indoor unit type Ceilling Concealed Duct - High Static ABNH186HLAB ABNH246HLAB ABNH306GLAB Model [UB18 NHB] [UB24 NHB] [UB30 NGB] Power Supply Ø/V/Hz 1 / 220 ~240 / 50 1 / 220 ~240 / 50 1 / 220 ~240 / 50 Cooling Capacity 5.28 7.03...
Page 50
- Level Difference of Zero. 2. Cooling/heating capacity of indoor unit can be lower when it is connected to MPS variable outdoor. 3. Wiring cable size must comply with the applicable local and national code. 50 Universal System Air Conditioner...
CN-D/PUMP DRAIN PUMP OUTPUT CN-REMO REMOTE CONTROL CN-DISP RF-REMOTE CONTROL CN-ROOM ROOM SENSOR CN-FLOAT FLOAT SWITCH INUT CN-AIRC AIR CLEAN CN-ZONE ZONE CONTROL OUTPUT CN-PTC PTC HEATER CN-CC CENTRAL CONTROL OUTPUT CN-OUT VENTILATION /ELECTRIC HEATER 52 Universal System Air Conditioner...
Slide switch for ceiling height (4) Close the rear cover and check if it works normally. CAUTION Select the position after checking duct work and E.S.P of the unit. • • Maunfactured in the position F-H. 54 Universal System Air Conditioner...
Page 55
Ceiling Concealed Duct How to Set E.S.P? Procedure of RPM change: Ex) External Static pressure is 4mmAq for Model Name "ABNH246HLAB". • To protect the unit, compressor is designed to be off during E.S.P. setting. Push the "On/Off" button. AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION...
Page 56
Value other than that in table will not give the combinations of airflow & ESP which are mentioned in the table. 2. Table 7-1 is based at 230V. According to the fluctuation of voltage, air flow rate varies. 56 Universal System Air Conditioner...
Page 57
Ceiling Concealed Duct Table 7-2 Static Pressure(mmAq) Setting Model Name Step Value CMM(CFM) High 22(777) 21(742) 19.8(669) 18.3(646) 16.5(583) ABNH186HLAB 18.5(653) 17.8(629) 17.1(604) 16.2(572) 14.5(512) [UB18 NHB] 16.1(569) 15.6(551) 15.1(533) 14.2(501) 13(459) High 24(848) 22.5(795) 20.8(735) 19(671) 18(636) ABNH246HLAB 21.3(752) 19.9(703) 18.7(660) 17.2(607)
8. Timer Cancel Button Used to cancel the timer. Display temperature can be different from actual room temperature if the remote controller is installed at the place where sun-rays are falling directly or the place nearby heat source. 58 Universal System Air Conditioner...
Ceiling Concealed Duct Optional Function • Wireless Remote Controller This air-conditioner is equipped with wired remote controller basically. But if you want to have the wireless remote controller, you pay for it. 1. FAN Operation Button Signal transmitter Used to circulate room air without cooling or heat- Transmits the signals to the signal receptor.
• The place where the unit is not affected by an electrical noise. • The place where air circulation in the room will be good . • There should not be any heat source or steam near the unit. 60 Universal System Air Conditioner...
Page 61
Ceiling Concealed Duct 9.2 Ceiling dimension and hanging bolt location Installation of Unit Install the unit above the ceiling correctly. CASE 1 POSITION OF SUSPENSION BOLT • Apply a joint-canvas between the unit and duct to absorb unnecessary vibration. • Apply a filter Accessory at air return hole. •...
Page 62
4) In Australia, the length of power supply cord measured from the entry of the power supply cord to the middle of live pin on the power plug should be over 1.8m. 62 Universal System Air Conditioner...
Ceiling Concealed Duct 9.4 Insulation THERMAL INSULATION All thermal insulation must comply with local requirement. INDOOR UNIT Union for liquid pipe Thermal insulator for refrigerant pipe (Local supply) Thermal insulator for Refrigerant pipe and thermal piping(Local supply) insulator(Local supply) Hose crip for thermal insulator (Local supply) Overlap with thermal Thermal insulator for refrigerant pipe...
Page 64
B ≥ 2C C ≥ 2 x SP SP = External Pressure (mmAq) 1/50~1/100 1/50~1/100 Ex) External Pressure U-Trap = 10mmAq Drain Pipe A ≥ 70mm B ≥ 40mm MAX 700mm C ≥ 20mm Drain Pump 64 Universal System Air Conditioner...
Ceiling Concealed Duct 10. Accessories Standard Accessories Screws for Insulation for Clamp (Other) Name Clamp metal Drain hose duct flanges fitting Quantity 1 EA 1 EA 1 set 6 EA 1 set • Owner's manual • Installation manual • Washers(8 pcs.) Shape for gas pipe for liquid pipe...
AUUW4860 [UU48 WUYB] AUUW6060 [UU60 WUYB] • Indoor Unit Matching LG’s system consist of one outdoor unit which can match with three different indoor units as individ- ual system. The indoor units are ceiling cassette, ceiling concealed duct and ceiling & floor types.
100 : 100,000 Btu/h 30 : 30,000 Btu/h 36 : 36,000 Btu/h 48 : 48,000 Btu/h Model Type W : Inverter Heat Pump H : Heat Pump Indicates that this is a R410A outdoor unit 68 Universal System Air Conditioner...
Page 69
MPS Inverter SINGLE A MPS Inverter SINGLE A (R410A·Outdoor Units) AUUW-B, AUUW-0 Contents 1. Features & Benefits ................70 2. Specifications..................72 3. Dimensional Drawings ................76 4. Wiring Diagrams ...................80 5. Piping Diagrams..................86 6. Electric Characteristics .................89 7. Operation Range...................90 8. Installation.....................91 Service Manual 69...
TPS Control 100% In case of low frequency operation Energy Saving Cooling Cooling load Capacity 1 compressor system *Condition fo trial : ISO5151 Constant Speed AC Inverter TPS Inverter(DC) Saving Zone 2 compressor system Operating Ratio 70 Universal System Air Conditioner...
Page 71
COP frequency and constant speed compressor covers rest load. COP of system is higher than DC Inverter Single system. Seasonal EER of DC Inv MPS is the best. Heating Capacity Improved 138%~133% • Using TPS technology, LG multi system 124% 120%~115% achieved world's best wide range of operation 112%...
MPS Inverter SINGLE A 3. Dimensional Drawings AUUW126B [UU12 WUEB]/AUUW186B [UU18 WUEB]/AUUW246B [UU24 WUEB] Air discharge grille Model AUUW126B [UU12 WUEB] AUUW246B [UU24 WUEB] AUUW186B [UU18 WUEB] Dimensions 74.5 74.5 Ø6.35 Ø6.35 Ø12.7 Ø12.7 76 Universal System Air Conditioner...
Page 77
MPS Inverter SINGLE A AUUW306B [UU30 WUEB] 4-holes for anchor bolts (Unit: mm) Number Name Descripition Liquid side service valve(mm) Ø6.35 Gas side service valve(mm) Ø15.88 Air discharge grill Control Cover Service Manual 77...
Page 78
MPS Inverter SINGLE A AUUW366B [UU36 WUHB] 4-hole for anchor bolts Control cover Liquid side 3-way valve Gas side 3-way valve Model AUUW366B [UU36 WUHB] Dimensions 1,165 1,135 Ø6.35 Ø15.88 78 Universal System Air Conditioner...
Page 79
MPS Inverter SINGLE A AUUW4860 [UU48 WUYB] AUUW6060 [UU60 WUYB] 500(bolt hole) Air outlet inlet inlet Service Panel Knockout hole (For the control wiring, the power supply, refrigerant connecting pipe) Knockout hole (For the control wiring, the power supply, (Unit : mm) refrigerant connecting pipe) Service Manual 79...
MPS Inverter SINGLE A 4. Wiring Diagrams AUUW126B [UU12 WUEB] 80 Universal System Air Conditioner...
Page 81
MPS Inverter SINGLE A AUUW186B [UU18 WUEB] OUTDOOR WIRING DIAGRAM INVERTER COMPRESSOR RD BL YL REACTOR CN-FAN(A) CN-COIL1 CN-COIL2 MAIN 4WAY CN-4WAY VALVE CN-TH1 CN-TH2 CN-TH3 (H/SINK) (AIR/PIPE) (SUC/DISP-I) LOW PRESS SWITCH CN-COM CN-PRESS CN-GND1 CN-GND2 GN/YL 1(L) 2(N) 1(L) 2(N) 3 POWER TO INDOOR SUPPLY...
Page 82
LOW PRESS CN-PRESS SWITCH OIL SEPERATOR CN-OIL/S CONSTANT RY-C/COMP COMPRESSOR CN-COM GND-1 GND-2 GN/YL 1(L) 2(N) 1(L) 2(N) 3 POWER TO INDOOR SUPPLY UNIT Notes: BLUE BLACK BROWN ORANGE WHITE YELLOW GN/YL GREEN/YELLOW FIELD WIRING 82 Universal System Air Conditioner...
LOW PRESSURE CN-PRESS NOISE FILTER SWITCH RELAY FUSE CONS-COMP 250V,20A GND-2 GND-1 GN/YL GN/YL 1(L) 2(N) 1(L) 2(N) 3 Power To Indoor Supply Unit Notes: BLUE BLACK BROWN ORANGE WHITE YELLOW GN/YL GREEN/YELLOW FIELD WIRING 84 Universal System Air Conditioner...
Page 85
MPS Inverter SINGLE A AUUW4860 [UU48 WUYB]/AUUW6060 [UU60 WUYB] INV-COMP(A) WIRING DIAGRAM RD BL REACTOR CN-FAN(A) CN-COIL1 CN-COIL2 4WAY CONS-COMP(B) CN-4WAY VALVE PIPE LENGTH NUMBER PIN S/W_ADDRESSING CN-C/COMP2 NUMBER PIN POWER NUMBER PIN RELAY MAIN OPTION PCB ASSY CRANKCASE CN-HEATER HEATER OPTION CRANKCASE...
MPS Inverter SINGLE A 6. Electric Characteristics Unit Power Compressor Model Type Voltage Voltage range AUUW126B 8.13 14.6 0.12 0.68 (UU12W UEB) AUUW186B 13.2 23.9 0.12 0.68 (UU18W UEB) AUUW246B 17.1 30.8 10/25 7.0/6.0 0.14 0.73 (UU24W UEB) AUUW306B Min. : 198 24.6 44.3 10/28...
Continuous Outdoor Unit operation [°C DB] Operative Indoor Unit [°C DB] Indoor Unit [°C DB] Operative: Intermittent operation due to the operational conditions (indoor/outdoor temperature, humidity, load etc.) can cause the heating capacity to decrease 90 Universal System Air Conditioner...
MPS Inverter SINGLE A 8. Installation 8.1 Select the best location • If a roof is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted. • Do not place animals and plants in the path of the warm air. •...
Page 92
D : 1000 mm or more A : 45 ˚ or more B : 200 mm or more E : Air outlet guide (procured at the site) C : 250 mm or more F : 250 mm or more 92 Universal System Air Conditioner...
MPS Inverter SINGLE A 8.2 Settlement of outdoor unit • Anchor the outdoor unit with a bolt and nut(ø10mm) tight- Tubing connection Bolt ly and horizontally on a concrete or rigid mount. • When installing on the wall, roof or rooftop, anchor the mounting base securely with a nail or wire assuming the influence of wind and earthquake.
Page 94
• Capacity is based on standard length and maximum allowance length is on the basis of reliability. • Improper refrigerant charge may result in abnormal cycle. • Oil trap should be installed every 10 meters. 94 Universal System Air Conditioner...
Troubleshooting Guide III. Troubleshooting Guide Self-diagnosis Function .................96 Cycle Troubleshooting Guide ................97 Electronic Parts Troubleshooting Guide ............98 General Information..................103 Service Manual 95...
Troubleshooting Guide Cycle Troubleshooting Guide Trouble analysis 1. Check temperature difference between intake and discharge air, and operating current. Temp. difference : approx. 0°C All amount of refrigerant leaked out. Current : less than 80% of Check refrigeration cycle. rated current Temp.
2) The output voltage of power power transfomer. transformer. 3) DC12V 3) Replace IC01D. 3) IC01D(7812) 4) DC5V 4) Replace IC02D. 4) IC02D(7805) 5) The voltage of micom pin 29 5) Replace IC01A. 5) IC01A(KIA7036) : DC4.5V↑ 98 Universal System Air Conditioner...
Page 99
Troubleshooting Guide Product doesn't operate with the remote controller. Trouble 2 Turn on main power. While the compressor has been stopped, the compressor does not operate owing to the delaying function for 3 minutes after stopped. When the compressor stopped Indoor Fan is driven by a low speed. At this point the wind speed is not controlled by the remote controller.
Page 100
DC 5V DC 0V Between IC01M(No. 10) and DC 1V↓ DC 12V Turn off main power. Check the electrical wiring diagram of Outdoor side. Check the open or short of connecting wires between Indoor and Outdoor. 100 Universal System Air Conditioner...
Page 101
Troubleshooting Guide When indoor Fan does not operate. Trouble 4 Turn off main power. Check the connection of CN-FAN. Check the Fan Motor. Check the Fuse(AC250V, T2A). Check the related circuit of indoor Fan Motor. • The pin No. of micom and the part for driving SSR.(Q01M) •...
MICOM - Between of IC01M - Between of IC01M If there are no problems after above checks. • Confirm the assembly condition that are catching and interfering parts in the link of the vertical louver 102 Universal System Air Conditioner...
Troubleshooting Guide General Information Error Indicator (Indoor) • The function is to self-diagnosis air conditioner and express the troubles if there is any trouble. • Error mark is displayed on display window of indoor units and wired-remote controller, and LED of outdoor unit control board.
Page 104
2 times 6 times PSC Fault 2 times 7 times DC Link High Volt 2 times 8 times Discharge Pipe Temp. High (INV) 3 times 2 times Discharge Pipe Temp. High (Cons.) 3 times 3 times 104 Universal System Air Conditioner...
Page 105
Troubleshooting Guide Error Indicator (Outdoor) Outdoor Error LED02G Outdoor Error LED01G Contents Case of error (Green) Status code (Red) CT Circuit 4 times CT Circuit malfunction D-pipe sensor INV. (open/ short) 4 times 1 time Open / Short Air sensor (open/ short) 4 times 4 times Open / Short...
Page 106
7. If the voltage of the sensor is 2.5Vdc at 25°C, then sensor is normal. 8. If the resistance of the sensor is 0 or 5Vdc, then sensor is abnormal. Repair or Change the PCB. 106 Universal System Air Conditioner...
Page 107
Troubleshooting Guide 2) Troubleshooting CH03 Display Title Cause of error Check point & Normal condition code • Connection of wire Communication • Open / Short • Main PCB Volt. DC12V Wired R/C • Wrong connection • Noise interference Wired R/C Indoor Unit CN-REMO 12Vdc...
Page 108
2. Check the resistance of float switch (Abnormal : Open, Normal : short) Check the float switch. 3. Check the level of water 4. Check the volt. Of Drain pump power supply. (AC 230V) Repair or Change the main PCB. 108 Universal System Air Conditioner...
Page 109
Troubleshooting Guide 4) Troubleshooting CH05, CH53 Display Title Cause of error Check point & Normal condition code • Power input AC 220V. (Outdoor, Indoor) • The connector for transmission is disconnected. • The connecting wires are misconnected. Communication • Communication poorly •...
Page 110
Normal : Over 2MΩ. 4. Check the resistance of compressor. Normal : 0.65Ω(INV), 0.8Ω(Cons.) No difference at each terminal. 5. Check the insulation from water at IPM part. Check the trace of water. 6. Check the IPM circuit. 110 Universal System Air Conditioner...
Page 111
Troubleshooting Guide 6) Troubleshooting CH21, CH22 Display Title Cause of error Check point & Normal condition code Malfunction of compressor Blocking of pipe Max. C/T Over current (14A ) Low voltage input Refrigerant, pipe length, blocked, … Malfunction of current detection circuit. (Open / Short) Initial current error Internal circuit...
Page 112
DC Link • DC link volt. is • Check the power source. High voltage 420Vdc . • Check the components. Check Point 1. Check the power source. 2. Check the components (B/Diode, Reactor, PSC Parts ) 112 Universal System Air Conditioner...
Page 113
Troubleshooting Guide 8) Troubleshooting CH24, CH25 Display Title Cause of error Check point & Normal condition code • Check the connection of “CN_Press”. • Low / High press Press S/W Open • Check the components. S/W open. • Abnormal Input voltage •...
Page 114
• CH 26 1. Check the component of “IGBT” 1. Check the connection of “U,V,W” 2. Check the components 2. Check the insulation of IPM part. (IGBT, R04S, NF1, BD02S) 3. Check the compressor. (same with CH21) 114 Universal System Air Conditioner...
Page 115
Troubleshooting Guide 10) Troubleshooting CH32, CH33 Display Title Cause of error Check point & Normal condition code • Check the discharge pipe sensor for INV. D-pipe (Inverter) • Check the install condition for over load. • Discharge sensor temp. high •...
Page 116
2. Estimate the voltage of each sensor.(Plugged) 3. If the resistance of the sensor is 0 kΩ or ∞, then sensor is abnormal. Ω If the voltage of the sensor is 0 V or 5Vdc, then sensor is abnormal. 116 Universal System Air Conditioner...
Page 117
Troubleshooting Guide 12) Troubleshooting CH51, CH60 Display Title Cause of error Check point & Normal condition code • Check the indoor unit capacity. • Over capacity Over capacity • Check the combination table. Combination EEPROM • Check the PCB ASM P/No. •...
Page 118
Check Point • CH 62 • CH 61 1. Check the fan is locked. 1. Check the install condition for over load. (Refrigerant, Pipe length, Blocked, …) 2. Check the Outdoor temp. is very high. 118 Universal System Air Conditioner...
Electronic Control Device IV. Electronic Control Device Ceiling Cacsette Type...................120 Ceiling Duct Type..................121 Celing & Floor ....................123 Service Manual 119...
Page 120
Electronic Control Device Ceiling Cacsette Type Main P.C.B ASM 120 Universal System Air Conditioner...
Speed Speed Speed Swirl Swing Control Vane 2 Vane 2, 4 is almost vane closed while vane1, 3 is opened. Vane 1, 3 and vane 2,4 turn over minutely Vane 1 Vane 3 Vane 4 130 Universal System Air Conditioner...
Ceiling Cassette Type Heating Mode Operation The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. Indoor unit 35°C Heat-Exchanger temperature 32°C 29°C 21°C 17°C Intake Air Temperature 3min Low fan during 10sec Setting Temperature +3°C (Thermo OFF)
Intake Air Temperature SET TEMPERATURE +0.5°C (Thermo. ON) SET TEMPERATURE -0.5°C (Thermo. OFF) More than More than 3 minutes 3 minutes Selecting Selecting Selecting INDOOR FAN fan speed fan speed fan speed COMPRESSOR 132 Universal System Air Conditioner...
Page 133
Ceiling Duct Type Heating Mode Operation The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. Indoor unit 40°C Heat-Exchanger temperature 33°C 30°C 27°C 20°C Intake Air Temperature 3min Low fan during 10sec Setting Temperature +3°C (Thermo OFF)
Page 134
• The indoor fan does not rotate until the indoor unit Hex-Exchanger temperature reaches 27°C. • The operation diagram is as following. Indoor unit Heat-Exchanger temperature 33°C 27°C 20°C 1min 1min Compressor Outdoor fan Setting fan Setting fan Indoor fan spped spped 4way Valve 134 Universal System Air Conditioner...
Ceiling & Floor Ceiling & Floor The function of main control Soft-Dry Operation • The indoor fan speed is automatically set to the low, so the shift of the indoor fan speed is impossible because of already being set to the best speed for Dry Operation by microcontroller control. Cooling Mode Operation •...
Page 136
While the indoor Heat-Exchanger temperature is higher than 35°C, fan operates at low speed, when it becomes lower than 35°C fan stops. For eluminating latent heat-loss, fan operates at low speed for 10 seconds periodically. 136 Universal System Air Conditioner...
Page 137
Ceiling & Floor Hot-Start Control • The indoor fan does not rotate until the indoor unit Hex-Exchanger temperature reaches 21°C. • The operation diagram is as following. Indoor unit Heat-Exchanger temperature 32°C 21°C 17°C 1min Compressor Outdoor fan Setting fan Setting fan Indoor fan spped...
Step_base Long piping Comp. Step compensation by setting long piping ∆Step_TAO step compensation by TAO (Outdoor temp.) ∆Step_TAI step compensation by TAI (Indoor temp.) ∆Step_DTAI Step Compensation of temperature difference Indoor Temp. and Setting Temp. 138 Universal System Air Conditioner...
Page 139
Outdoor Units Target frequency step (Step_base) exceeds maximum step, the Step_base value follows the maximum step value. The compressor get the minimum step in case Step_base value is lower than the minimum step of operating capacity. Compressor operation range Control Capacity Inv.
- LEV pulse down : T target > 18°C (3) Target Temperature Control (Heating mode) - LEV pulse up : T target > Tout - LEV pulse down : T target < Tout (4) LEV pulse change Value 140 Universal System Air Conditioner...
Outdoor Units 1.4 Fan control Control logic of outdoor fan depends on Outdoor temperature. (1) Single fan model (2) Two fan model Step_Fan Fan (A) Fan (B) Step_Fan Fan A High High High High Outdoor Cooling Single FAN Cooling two FAN temperature Step_Fan + 2 41°C...
4) Fan of outdoor unit is ON with high speed and maintain it after 5 seconds from the time of 30Hz. 5) Hot Gas bypass valve/Oil separator bypass valve make OFF after 75 seconds from the time of 30Hz. 142 Universal System Air Conditioner...
Outdoor Units 2.2 Low ambient control Low ambient cooling case : In this situation outdoor fan works in ON/OFF control. : If the pipe temperature 0°C and it is falling rapidly in that case compressor will run for 5 min & then it will go in low ambient control.
3) During this operation,if operating Hz couldn’t be changed by safety control ,stop this operation. Operating process : Raise the operating HZ up to 70,and after 20 sec.(option) recover to the last value. 144 Universal System Air Conditioner...
Page 145
Outdoor Units 2.5 Sump heating control 2.5.1 Inverter compressor sump heating fuction : A function protecting inverter compressor from damages, by increasing oil viscosity in low outdoor temperature. For the control,compressor operates in low frequencies. Operating condition :in case of the following 3 conditions are fulfilled at the same time. - Outdoor temperature, D-pipe temperature, Heat sink temperature : below 0°C, OD temp.
10 pulse in every 1 min. (c) Discharge pipe temperature ≥ Toff Compressor will be off D-Pipe temp Toff(105)°C T2(95)°C T1(90)°C 5 Hz 5 Hz COMP Down Down Expansion Stop control Pulse Up Pulse Up valve 146 Universal System Air Conditioner...
Page 147
Outdoor Units 3.1.2 Discharge pipe control for constant compressor 1) There can be two situations (a) Sensor is failed (error code for sensor failure will be generated) (b) Abnormal high temperature discharge temperature (error code for high discharge will be generated) Both cases unit will stop.
Page 148
And after 3 min turn on the compressor and check the current again. b) If CT2 occurs 5 times in 1 hour,stop the operation and shows Self-Diagnosis Error Mode 22 Model cooling heating CT 2 (CT 1) (CT 1) 18k~36k 48~60k 148 Universal System Air Conditioner...
Page 149
Outdoor Units 3.3 Inverter Protection control(2) 3.3.1 Function : Power module failure protection by checking the temperature of heat sink. There is a temperature sensor for checking the heat sink temperature. 3.3.2 Heat sink sensor failure error Short Check : if temperature ≥130°C Open Check : if temperature <...
Page 150
Exploded View & Replacement Parts List VII. Exploded View & Replacement Parts List Indoor Unit ....................151 Outdoor Unit ....................169 Panel Assembly, Front .................179 150 Universal System Air Conditioner...
Page 151
Exploded View & Replacement Parts List Ceiling Cassette 4-way Ceiling Cassette Type ATNH-EL 266090 249951 268714 263230-1 159830 354211 35211A 352118 263230-2 263230-3 354211 158591 330870 266012 Service Manual 151...
Page 152
Exploded View & Replacement Parts List 130411 W0CZZ 346811 359011 130911-2 130911-1 152150 152150-2 267110-1 267110-2 152 Universal System Air Conditioner...
Page 153
Exploded View & Replacement Parts List ATNH-FL 349490 266090 249951 354211-2 268714 354211-1 263230-1 159830 352118-2 263230-2 552111 263230-3 352118-1 158591 266012 330870 Service Manual 153...
Page 154
Exploded View & Replacement Parts List 130411 W48300 W48300 W0CZZ 346810 359012 130911-2 152150-1 130911-1 152150-2 267110-2 267110-1 154 Universal System Air Conditioner...
Page 155
Exploded View & Replacement Parts List ATNH-DL 249941 249951 266090 268714 159830 263230-1 354211-2 130411 354211-1 352118-2 263230-2 552111 263230-3 352118-1 330870 158591 266012 Service Manual 155...
Page 156
Exploded View & Replacement Parts List 130411 W0CZZ 349600 346810 359012 130911-2 352150 130911-1 267110-1 267110-2 352150-2 156 Universal System Air Conditioner...
Page 157
Exploded View & Replacement Parts List Parts List Part No. LOCATION DESCRIPTION SVC CODE ATNH126ELFB ATNH186ELFB [UT12 NEB] [UT18 NEB] 130411 BASE ASSEMBLY,WELD(INDOOR) 3041A10013A 3041A10013A 130911-1 CABINET ASSEMBLY,INDOOR 3091A10023C 3091A10023C 130911-2 CABINET ASSEMBLY,INDOOR 3091A10023D 3091A10023D 158591 PUMP ASSEMBLY,WATER 5859A20001M 5859A20001M 159830 AIR CLEANER ASSEMBLY 5983A10002A...