Cropping ..................35 9.3.5 OSD ....................36 Alarm ......................36 9.4.1 Alarm....................37 9.4.2 Audio Upload .................39 9.4.3 Alarm Server ..................39 Record......................40 9.5.1 FTP Recording................40 9.5.2 SD Recording.................43 9.5.3 E-Mail Recording ................45 Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 4
Temperature...................57 9.11 Logbook......................57 9.12 Licence information ..................57 Utility program application.................58 10.1 NAS player setup ..................58 10.2 Audio record setup ..................58 10.3 Firmware update setup..................59 Maintenance....................60 Disposal......................61 Index ......................62 Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
The environmental conditions recommended by the manufacturer must be observed. See section “Technical data”. Do not operate the device in dusty places. Do not expose the device to mechanical vibrations or shocks. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Compliance with the European Directive 2004/108/EC has been proven by testing according to the following standards: Emitted interference: EN 61000-6-3 EN 55022 Class B Interference resistance: EN 50130-4 Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
On/Off, BLC1 – BLC6 (BLC) Audio Two-way audio; full-duplex, G.726 (integrated microphone) Alarm inputs Alarm outputs Telemetry protocol RS485 SD card slot 2 GB SD-RAM included in scope of delivery Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 8
< 7 W Power connector 2-pin spring terminal Environment Ambient temperature, -10 to +50 ºC operating Relative humidity 80 % (operating) or less Ambient temperature, storage -20 to +60 ºC Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 9
Technical data Mechanism Angle control (3-axis) Pan travel 350º Tilt travel 146º Dimensions (H x D) 128 x 140 mm Weight 0.65 kg Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
MON (Monitor out connector) Default button IP/TV selection Microphone Loosen the locking screw Front cover screw Open/close dome indication Dome cover Fixed point for ceiling mount Pan adjustment bracket Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 12
IP TV purpose NOTE: After switching between IP and TV the camera has to be restarted Default button DEFAULT Return to factory default by pressing button for 5 seconds Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
The camera can be used in various indoor environments. It can deliver video images and audio in real time using the Internet or an intranet. The camera is equipped with Ethernet (RJ-45) 10BASE-T/100BASE-TX network interfaces. Ethernet Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
If your network uses a DHCP server, you do not need to change the IP address of the camera. But be sure to set DHCP ON/OFF to ON in "Network settings/Basic". Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 15
Set the IP address of your PC to other than 192.168.0.10 (Camera's default − IP address). E.g. set the IP address to 192.168.0.20 (and subnet mask to 255.255.255.0). Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
To search a camera in the network: 1. Start the Web-Cam IP Manager (The file is included on the utilities CD). The Web-Cam IP Manager program window will open: Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
2. Select Internet option on the tools menu and click the Security tab. 3. Click the Local intranet icon if the camera is inside the Intranet. - OR - Click the Internet icon if the camera is on the Internet. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 18
When using the network cameras via a proxy server it may take a long time for the images to be displayed after log-in, or the frame rate of the images may be reduced. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
The administrator login allows rewriting of all settings. Change the default administrator user name and password to ensure camera security. See page [ 52] . 5. Click OK. 6. The homepage of the camera will appear. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Before using this function, please set the baud rate and address of the telemetry device for control via the RS485 port. NOTE: Not available for this camera type. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
The VLC media player needs to be installed. 1. Open the VLC media player. 2. Select Media > Advanced Open File, then click the Network tab. The following dialog box will appear. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
The following dialog box will appear. 3. Enter the web address. The format is: rtsp://<IP address>:<rtsp_port>/livestream For example: rtsp://192.168.0.194:554/livestream 4. Click OK. The VLC live stream window will open. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Sets quality of images. The size of image files – Ratio (JPEG files) varies in accordance with compression ratio. Select “Low” for highest image quality. The file size increases. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 25
Number is 554 VIDEO Port Specify the port number you would like to use for video streaming, Number default is 5000 See also Using a RTSP player [ Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
NOTE: The bandwidth for MPEG4 streaming is selectable and is therefore not listed in table. Network settings 9.2.1 Basic 1. Select Network > Basic. 2. Configure the options as described in the table below. 3. Click Save. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 28
Secondary DNS (same as above) Port Stream 1-2, We recommend using the default port; if you need to change the default Cropping 1-5 port, please contact your system administrator. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Select ON to enable the DDNS function. DDNS Server Select your DDNS server (DnyDNS or DHS). Host Name Enter the host name. Domain Name Enter the domain name. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Select the max. number of simultaneous connections. Simultaneous Connections Image parameters 9.3.1 Basic 1. Select Image Parameters > Basic. 2. Configure the options as described in the tables below. 3. Click Save. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 31
The Slow speed shutter can be turned on if the sensitivity is still not Shutter sufficient under automatic gain condition at dark. The optimum image level can be maintained by appropriate gain and shutter combination Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 32
Set the offset level to adjust the image level for a DC auto iris lens. The higher the level, the brighter the images and the lower the level, the darker the images. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Select the time for which the camera will stop at each position during scanning between 5 and 60 s Preset selection Select the presets between 1 and 64 that will be called during the patrol. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
3. Use the mouse to drag a mask rectangle on the screen. 4. Click OK to finish the setting, and return to the Mask Zone menu. 5. Click Save to enable the mask settings. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
5. Click OK to finish the setting, and return to the Cropping menu. 6. Click Save. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
For example, by mounting a sensor to a door, an alarm will be triggered each time the door is opened. By setting the integrated motion/activity detection, an alarm will be notified when a change is detected by the camera. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
AUDIO out jack on the rear panel. Event Select the pre-recorded sound file (on the SD card) to be output as a sound alarm. See page [ 39] . Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 38
OFF: Alarm out disabled Event: When alarm input 1 or alarm input 2 is triggered or motion is detected, the alarm out will be triggered immediately as well. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Define the target alarm server port number. Alarm-input message Define the message (up to 64 characters) to be sent to the alarm server when an alarm input is triggered. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
PASV: This mode is used when the camera's network environment is behind a firewall. FTP Connecting Reconnect: The network camera logs in/out for each file transfer Method Continuous Connection: The network camera is always in connection. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 41
Accumulation Set a time interval in seconds for images to be stored. Cycle Overwrite Overwrite when SD card reaches the maximum capacity and start with oldest stored images. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
You can enter the file name or leave it blank. Server Path Enter the data path where the data is to be stored on the server. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Enter the data path where the data to be stored on the server. 9.5.2 SD Recording 1. Select Record > SD Recording. 2. Configure the options as described in the table below. 3. Press Save. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 44
Determine the recording condition (STOP, All Day, Schedule 1 or Schedule 2) for all days from Monday to Sunday. Schedule 1, Determine the recording time. Schedule 2 Recording cycle Set a time interval for recording images. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
You can receive images by setting your e-mail account. 1. Select Record > E-mail Recording. 2. Configure the options as described in the table below. 3. Click Save. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 46
(POP) E-mail User ID Enter your e-mail account ID number Password Enter your e-mail account password Password Confirm your e-mail password (Confirm) Administrator Enter the administrator’s e-mail address Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 47
Determine the recording condition (STOP, All Day, Schedule 1 or Schedule 2) for all days from Monday to Sunday. Schedule 1, Determine the record time. Schedule 2 Recording Cycle Set a time interval for schedule recording. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Recording on NAS drives is intended for short video sequences and images. 1. Select Record > NAS Recording. 2. Configure the options as described in the table below. 3. Click Save. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Page 49
Determine the recording condition (STOP, All Day, Schedule 1 or Schedule 2) for all days from Monday to Sunday. Schedule 1, Determine the recording time. Schedule 2 Recording cycle Set a time interval for recording images. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
2. Configure the options as described in the table below. 3. Click Save. Audio Input ON: The external microphone input or integrated microphone is activated. OFF: The external microphone input or integrated microphone is Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
3. Click Save. Display Select ON to display date/time on screen. NOTE: The position and colour can be set on the camera OSD menu. See also page [ 36] . Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Select your individual language of the user interface. Logoff Time Enter the time (sec) after which the administrator will automatically be logged off. OFF means no automatic log off. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
All the IP addresses listed and enabled in this section will be allowed or denied to pass the firewall. 1. Select Firewall > IP Address Filter. 2. Configure the options as described in the table below. 3. Click Save. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
All the ports listed and enabled in this section will be forbidden to pass the firewall. 1. Select Firewall > Forbidden Ports. 2. Enter the port number and click Enable to have this port rejected by the firewall. 3. Click Save. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Close all programs on the PC before starting a firmware update. Never disconnect power and LAN cables during the firmware update process. 1. Select System > Update. 2. Select the firmware file using the Browse button. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Clicking the Default button will reset the camera settings to the Default factory default values. NOTE: Basic settings of the IP camera such as the network IP address and the camera name will not be reset. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
1. Select Log. 2. Click the buttons to display the desired logbooks or to delete all logs. 9.12 Licence information Select Notice. All licence information for the camera will shown. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
3. Install a speaker before you start recording your voice. 4. Click on red button and start recording your voice. 5. Click on Stop button. 6. Recording is now finished Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
4. Click on the Browser button and choose the network camera SW version. 5. Click on the Upload button for firmware update. 6. The update is now finished. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...
Do not touch the lens area. Use a soft cloth moistened with alcohol to clean the surface if it is touched accidentally. Defective modules should be sent to the nearest Siemens office to be forwarded to the service centre. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety &...
For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product. Building Technologies CFMC1315-LP Configuration Manual EN Fire Safety & Security Products 05/05/2009...