Communication Settings; List Of The Communication Settings; Operation; Protocol Setting - LG LCC-K1000 Owner's Manual

Dynamic controller
Table of Contents

Advertisement

LCC-K1000_AABBLLG_ENG

Communication Settings

This setting is required to establish a connection
between the system units and system controller.

List of the communication settings

Setting Item Available setting parameter(s)

Protocol Setting:

LG MULTIX / LG old /
Reserved 1-6
Communication Speed (Baud Rate):
9,600 / 1,200 / 2,400 / 4,800 /
19,200 / 38,400 / 57,600 /
115,200 bps

Parity Bit:

NONE / ODD Parity /
EVEN Parity

Set Data Bits:

8 Data Bits / 9 Data Bits

Stop Bit:

1 bit (Fixed)
Note: Factory defaults are underlined.

Operation

PRESET

1. Press the Set Up button then select the
[Communications] icon.
COMMUNICATION
2. Press SEL.
The sub menu will appear for [COMMUNICATION]
setting.

Protocol Setting

Communication Speed

PTZ
Parity Bit
000
3. Press the PTZ1 or PTZ2 button then use number
buttons to select a camera's number, if required.
4. Press SEL.
5. Use Arrow (M / m) buttons to select a desired
option then press SEL.
The display will change to the editing mode.
6. Use Arrow (M / m) button to select the desired set-
ting then press SEL to confirm your selection.
8/9/05
2:55 PM
Page 11
000
PTZ
000
PTZ
[vV:bB]
Protocol Setting
This item lets you set a protocol for RS-485 commu-
nication.
You can select the desired parameter from
[LG MULTIX], [LG old], and [Reserved 1-6].
Communication Speed (Baud Rate)
Setting
The speed of communication between the system
controller and other system units.
You can select the desired parameter from 9,600 /
1,200 / 2,400 / 4,800 / 19,200 / 38,400 / 57,600 /
115,200 bps
Note: Conform this parameter to the baud rate of
other system units. Otherwise, communication will
not be established between the system controller and
system units.
Parity bit
The parity bit, added to the data, to perform parity
check.
You can select the desired parameter from [NONE],
[ODD Parity], and [EVEN Parity].
Data Bits Setting
This item lets you set the number of the data bits for
RS-485 communication.
You can select the desired parameter from [8 Data
Bits] and [9 Data Bits].
Note: This setting must be compatible with the
peripherals connected.
Stop Bit Setting
The stop bit, added to the last of data, in
asynchronous communication.
The parameter is fixed to [1bit].
11