hit counter script

LG AS-W096URH0/UBH0/UWH0/UMH0 Service Manual page 36

Lg room air conditioner
Table of Contents

Advertisement

Operation
Healthy Dehumidification mode operation
• When the dehumidification operation is set by the remote controller the intake air temperature is detected and
the setting temp. is automatically set according to the intake air temperature.
Intake air Temp.
26°C ≤ intake air temp.
24°C ≤ intake air temp.< 26°C
18°C < intake air temp. < 24°C
intake air temp. ≤ 18°C
• When intake air temp reaches above the temp of setting +1.0°C, condition of compressor same as cooling
mode operation.
• When intake air temperature reaches bolow the temp of setting –1.0°C, compressor operate step1~step3 and
indoor fan speed repeatly operate low or stop.
36 Room Air Conditioner
Setting Temp.
25°C
intake air temp. -1°C
intake air temp. -0.5°C
18°C

Advertisement

Table of Contents
loading

Table of Contents