hit counter script

How To Fix Installation Plate; Drill A Hole In The Wall; Drain Hose Junction - LG TS-C096EMA0 Service Manual

Room air conditioner
Table of Contents

Advertisement

How to Fix Installation Plate

The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with four
type A screws. If mounting the unit on a concrete
wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
Installation Plate
Chassis
Hook
2. Measure the wall and mark the centerline. It is
also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi-
cally. Drilling the hole through the wall for pip-
ing connections must be done safely.
Installation plate
D
B
C
Ø70mm
Left rear piping
CHASSIS
(Grade)
A
7k, 9k, 12k
75
18k, 24k
105
Type "A" screw
A
Ø70mm
Right rear piping
Distance (mm)
B
C
D
65
105
65
65
260
65

Drill a Hole in the Wall

• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
WALL
Indoor
• Open the Front Grille.
• Pass Telephone Control Cord Wire through the hole
which the power cord goes through.
• Connect Telephone Control Cord Wire to the phone jack
of telephone PCB of Control Box.
• Fix Telephone Control Cord Wire inside Control box so
as not to disconnect.
• Close the Front Grille.

Drain hose junction

• Remove the rubber stopple in the desired drain direc-
tion.
• Insert drain hose into the handle of drain pan, and join
drain hose and connecting hose according to the figure
by.
Only the
desired direction
Installation
Outdoor
Adhesive
Connecting
part
Drain
hose
Service Manual 19

Advertisement

Table of Contents
loading

Table of Contents

Uploaded: cache9/manual/748005/Lg-Ts-C096ema0.html%3Fpage%3D19.gz