Summary of Contents for Frigidaire LI30MB

  • Page 1 USA 1-800-944-9044 Canada 1-800-265-8352 www.frigidaire.com www.frigidaire.ca LI30MB / 316902497 Feb/13...
  • Page 2: Table Of Contents

    Location requirements .......... 6 Product dimensions ..........6 Product Registration Venting Requirements .......... 7 Registering your product with Frigidaire enhances our Prepare the location ..........8 ability to serve you. You can register online at Install Range Hood (Ducted version) ..... 10 www.frigidaire.com or by dropping your Product...
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using this appliance. Save these instructions for future references WARNING Approved for residential appliances TO REDUCE THE RISK OF FIRE, ELECTRIC For residential use only SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Do not attempt to install or operate your appliance until Use this unit only in the manner intended by the you have read the safety precautions in this manual.
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS WARNING WARNING To Reduce The Risk Of Fire Or Electric Shock, Do TO REDUCE THE RISK OF INJURY TO PERSONS, Not Use This Hood With Any External Solid State IN THE EVENT OF A RANGE TOP GREASE FIRE, Speed Control Device.
  • Page 5: List Of Materials

    LIST OF MATERIALS LIST OF MATERIALS ELECTRICAL REQUIREMENTS Parts included in your hood Observe all governing codes and ordinances. 4 - 0.45 x 1.3 cm mounting screws Ensure that the electrical installation is adequate and in • 2 - .35 x .65 cm rectangular vent transition conformance with National Electrical Code, ANSI/NFPA •...
  • Page 6: Location Requirements

    LOCATION REQUIREMENTS Cabinet Dimensions IMPORTANT Observe all governing codes and ordinances. It is the installer’s responsibility to comply with • installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the left side (See page 2 for location).
  • Page 7: Venting Requirements

    VENTING REQUIREMENTS Vent system must terminate to the outdoors. • Roof Venting Wall Venting Do not terminate the vent system into an attic or other • enclosed area. Do not use a 4” (10.2 cm) laundry-type wall cap. • Use a 3¼” x 10” (8.3 x 25.4 cm) rectangular or 7” (17.8 •...
  • Page 8: Prepare The Location

    VENTING REQUIREMENTS PREPARE THE LOCATION ¼” x 10” (8.3 cm x 25.4 cm) Vent System Vent Piece NOTE 3¼” x 10” (8.3 cm x 25.4 cm) 5.0 ft 90° elbow (1.5 m) Before making cutouts, make sure there is proper clearance within the ceiling or wall. 3¼”...
  • Page 9 PREPARE THE LOCATION To wire through top: Style 2 - Cut Openings for 3¼” x 10” (8.3 cm x Mark a line distance (A) from the right of the .4 cm) Rectangular Vent System centerline on the underside of the cabinet. Mark the point on this line that is ⁄...
  • Page 10: Install Range Hood (Ducted Version)

    PREPARE THE LOCATION Style 3 - Cut Openings for 3¼” x 10” (8.3 x 25.4 Install Vent System cm) Rectangular Vent Transition to Round Vent Install vent through the vent opening in upper cabinet or wall. Complete venting system according to the Roof Venting selected venting method.
  • Page 11: Installing The Hood

    INSTALLING THE HOOD Vent Connector Installation Lift the range hood up under cabinet and determine Install 7” (17.8 cm) round vent mounting plate or 3¼” x final location by centering beneath cabinet. Mark on 10” (8.3 x 25.4 cm) vent connector, depending on your the underside of cabinet the location of the 4 keyhole vent system installation.
  • Page 12: Make Electrical Connection

    INSTALLING THE HOOD 1. Disconnect power. NOTE A.White wires B. Black wires Do not reconnect power until the installation is C. UL listed wire connector D. Green (or bare) ground wire complete. E. Home power supply cable Before starting the installation, remove the F.
  • Page 13: Installing Range Hood (Recirculating Version)

    INSTALLING THE HOOD INSTALL RANGE HOOD Remove the power supply knockout from the top or rear of the vent hood (depending on the incoming (Recirculating version) location of your home power supply cable) and install a UL listed or CSA approved ½” strain relief. Lift the range hood up under cabinet and determine final location by centering beneath cabinet.
  • Page 14: Range Hood Use

    RANGE HOOD USE RANGE HOOD USE Cleaning The range hood is designed to remove smoke and cook- WARNING ing vapors from the cooktop area. For best results, start the hood before cooking and allow it to operate several To Reduce The Risk Of Fire Or Electrical shock minutes after the cooking is complete to clear all smoke disconnect from power supply before cleaning.
  • Page 15 RANGE HOOD CARE To clean grease filter, soak the filters in hot water using Disconnect power. a mild detergent. Rinse well and shake to dry. Or place Push up on the lens and turn it in upper rack of dishwasher to clean. counterclockwise.
  • Page 16: Troubleshooting

    TROUBLESHOOTING Problem Possible Causes Solutions After installation, 1. The power line and the cable locking 1. Check the power connection with the unit is the unit doesn’t connector is not connecting properly. connected properly. work. 2. The wires from the switches are disconnected 2.
  • Page 17: Warranty Information

    Warranty Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolux will repair or replace any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained in accordance with the provided instructions.